    ISSN: 1432-1238
    Keywords: Auto-PEEP ; COPD ; Pressure support ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We report a case of hyperinflation induced isorythmic atrio-ventricular dissociation with circulatory failure in a patient with chronic obstructive pulmonary disease. The arrythmia was successfully treated by applying “pressure support ventilation” (PSV: 20 cmH2O) which, by decreasing the respiratory rate and increasing the expiratory time reduced the level of auto-PEEP. In order to explain this result the Authors recorded, in the same patient, the level of auto-PEEP and ΔFRC obtained with Intermittent Positive Pressure Ventilation (IPPV), Intermittent Mandatory Ventilation (IMV) and PSV at the same gas exchange values. PSV showed a dramatic reduction of both these parameters. (Auto-PEEP: IPPV 12 cmH2O, IMV 17 cmH2O, PSV 7 cmH2O).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1238
    Keywords: COPD ; High frequency jet ventilation ; Auto-PEEP
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We investigated the levels of auto-PEEP and dynamic hyperinflation during high frequency jet ventilation (HFJV) and controlled mechanical ventilation (CMV) in six patients with chronic obstructive pulmonary disease within the first 36 h of acute exacerbation. The comparative evaluation was performed at similar conditions of gas exchange in HFJV and CMV: PaO2 77.6±11 mmHg vs 80.8±12 mmHg; PaCO2 46.8±2.5 mmHg vs 47±2.8 mmHg; pH 7.38 vs 7.38. In this situation, the values of auto-PEEP and dynamic hyperinflation, expressed as Δ over the apneic functional residual capacity (FRC) did not differ: (auto-PEEPHFJV 8.9±3.8 cmH2O; auto-PEEPCMV 8.8±4.7 cmH2O; ΔFRCHFJV 0.56±0.19 l; ΔFRCCMV 0.54±0.2 l). This result suggests that, with a suitable machine setting and similar gas exchanges, HFJV produces the same level of auto-PEEP and dynamic hyperinflation as CMV in patients with chronic obstructive pulmonary disease.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Heat-moisture exchangers ; COPD ; Auto PEEP ; Controlled mechanical ventilation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In recent years the use of devices called Heat and Moisture Exchangers (HME) has become widespread as gas conditioners for ICU patients requiring mechanical ventilation. As an important variation of the resistive properties of the HME, related to flow and duration of use, has recently been pointed out during “in vitro” studies, the use of these devices in COPD patients could increase the levels of auto PEEP and dynamic hyperinflation. In this study we have compared the levels of auto PEEP and difference in functional residual capacity (Δ FRC) in a group of COPD patients, requiring controlled mechanical ventilation (CMV), at basal conditions and after the insertion into the circuit of three HMEs (Dar Hygrobac, Pall Ultipor, Engstrom Edith) at random: the results obtained excluded a significant increase of auto PEEP and Δ (FRC) both with “new” HMEs and after 12 h of continuous use.