Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 555-560 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused-silica ; Plasma amino acid analysis ; “On-column” injection ; Classical ion exchange ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p 〈 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p 〈 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 4 (1981), S. 218-223 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Column preparation ; “Split” vs. “on-column” injection ; Amino acid analysis, quantitative 10 ng level ; Average relative standard deviation 1% ; Fish muscle protein analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A carefully Standardized technique is described for the preparation of glass capillary columns which can be used successfully for routine quantitative amino acid analysis. Comparison is made between two different modes of sample injection. Preliminary quantitative results from “split” injection and “on-column” injection techniques are evaluated statistically and it is concluded that the “on-column” system is a prerequisite for quantitative amino acid analysis by glass capillary gas chromatography. An analysis of fish muscle protein hydrolyzate illustrates an application of this technique and results are compared with those from a packed column analysis.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...