Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Anion-exchange stationary phases ; Polymer coating ; Cross-linking
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary PHEB=POLY(2-hydroxy, 3N-ethylenediamino)butadiene has been synthesized. This unsaturated pre-polymer can be immobilized on different, preferably inorganic supports of suitable porosity such as silica or alumina by cross-linking. Weak anion-exchange phase are obtained. Such phases do not have the disadvantages of organic polymeric phases, regarding pressure stability and swelling by solvent influence. The ion-exchange capacity and the retentivity of IE-separations can deliberately be varied via the thickness of the cross-linked polymer layer. Alumina can also be coated with PHEB applying the same cross-linking procedure. Such phases exhibit an exceptional chemical stability even when operated with mobile phases at very high pH-values. Separations of excellent selectivity are achieved for inorganic anions, as well as with mixtures of aliphatic and aromatic free acids also including hydroxy- (mono- or poly)carboxylic acids.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 191-197 
    ISSN: 0935-6304
    Keywords: Capillary SFC ; Instrumentation ; Sampling techniques ; Restrictors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Different designs of injection and restriction devices for capillary supercritical fluid chromatography (SFC) have been investigated with respect to their practical applicability and usefulness for reproducible and accurate qualitative and quantitative analyses. In combination with a self-made instrument a fast switching valve is preferable as an injection device compared to a split-injector, and an integral restrictor made from the end of the fused silica (FS) separation column was superior to a linear restrictor made by coupling a small diameter FS-column to the separation column.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...