Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 50 (1983), S. 195-206 
    ISSN: 1439-6327
    Keywords: Blood volume ; Plasma protein ; Bicycle exercise ; Skin temperature ; Core temperature
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The effects of alterations in mean skin temperature (¯Tsk) on intravascular volume and protein responses to 90 min of bicycle ergometer exercise have been studied in six male subjects. The onset of exercise was accompanied by an initial rapid haemoconcentration, followed by a slower, progressive haemoconcentration as core and skin temperatures increased. Cooling the skin after 30 min of exercise abolished the slow haemoconcentration, and thereafter, even when Tsk was raised to the pre-exercise level during the final 30 min of exercise, little further change in blood volume was observed. During skin warming, and during recovery from exercise, there was an increase in the total intravascular protein content compared with before exercise. It is concluded that the progressive haemoconcentration often described during cycling exercise may be attributed to an increase in skin blood flow occurring as a result of rises in core and skin temperature, the associated increase in filtration through the cutaneous capillaries causing a progressive loss of plasma volume. The mechanism of the augmentation of intravascular protein remains unclear.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 55 (1986), S. 187-194 
    ISSN: 1439-6327
    Keywords: Blood volume ; protein ; Blood pressure ; Heart rate ; Head-up tilt
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Experiments were undertaken to determine the effects of hydration status on a) orthostatic responses, and on b), relative changes in intravascular volume and protein content, during 70
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    European journal of applied physiology 56 (1987), S. 673-678 
    ISSN: 1439-6327
    Keywords: Blood volume ; Plasma volume ; Specific gravity ; Capillary filtration ; Ultrafiltrate ; Albumin ; Globulins ; Haematocrit
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28–49 years) undertook 30 min of standing immersion in water at 35.0±0.2
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Electrophoresis 19 (1998), S. 6-10 
    ISSN: 0173-0835
    Keywords: Capillary electrophoresis ; Vitreous humor ; Potassium ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: Capillary ion analysis (CIA) is a form of capillary electrophoresis which uses the differential electrophoretic mobility of ions to perform a separation of an ionic mixture. Application of this technique for direct detection of potassium concentrations in human vitreous humor was the purpose of this investigation. CIA was performed using a Waters Quanta 4000 Capillary Electrophoresis System with a 745 Data Module using a 75 μm × 60 cm capillary and a run electrolyte of 67.7 mg hydroxyisobutyric acid (HIBA), 52.8 mg 18-crown-6 ether and 64 μL UV-CAT-1 reagent (4-ethylbenzylamine) in a volume of 100 mL water (18 Mohm) with a voltage of 20 kV using ultraviolet absorption detection at 214 nm. Migration times were: ammonium ion, 2.86 min; potassium, 3.24 min; calcium, 3.84 min; sodium, 3.98 min; barium (internal standard), 4.68 min; and lithium, 4.79 min. Correlation coefficients (r) between peak area ratios and concentration ranges of 2.5-144 mmole/L (100-1000 ppm) were from 0.9855 to 0.9999. Coefficients of variation (CV) ranged from 1.45 to 13.8% between days and from 1.38 to 9.43% within-day. Application of this methodology to twenty-five vitreous humor specimens from forensic cases was compared to analysis by ion-specific electrode for potassium concentration. Comparison of CIA to ion-specific electrode analysis of vitreous humor potassium concentrations revealed a correlation coefficient of 0.9642. CIA is applicable to forensic analysis of potassium concentration in forensic vitreous humor specimens. Quantitation of numerous cation concentrations is possible by direct CIA of vitreous humor.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...