Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-1920
    Keywords: Magnetic resonance angiography ; Carotid arteries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Magnetic resonance angiography (MRA) hs inherent artifacts due to variation in velocity and direction of flowing blood in the carotid bulb and regions of stenosis. We examined the efficiency of dual 3-inch surface coils to delineate carotid artery flow better. Carotid MRA was performed on ten healthy volunteers and six patients, on a 1.5 T system. A special adapter was constructed to use with 3-inch (receive-only) coils, which were placed over the carotid bifurcations. Routine anterior neck coils were also used. Contiguous axial two-dimensional (45/8.7, 1.5 mm, flip angle 60°) time-of-flight sequences were used. Image matrix was 256×256 with two signals averaged and acquisition time 6–10 min. These images were postprocessed and reformatted into angiographic views using a maximum intensity projection algorithm. Computer simulation of carotid artery blood flow through-out the cardiac cycle based on vessel contours derived from digital subtraction angiography was carried out by finite element analysis. Improved definition of vessel margin, particularly at the carotid bifurcation, and substantially increased signal-to-background ratio of flowing blood were obtained with 3-inchcoils. Apparent loss of signal in the carotid bulb was diminished. In one patient, contiguous flow throughout a high-grade stenosis was well defined, with the surface coil method, while drop-off of signal was observed with routine neck coil imaging.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-1920
    Keywords: Key words Magnetic resonance angiography ; Carotid arteries
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Magnetic resonance angiography (MRA) hs inherent artifacts due to variation in velocity and direction of flowing blood in the carotid bulb and regions of stenosis. We examined the efficiency of dual 3-inch surface coils to delineate carotid artery flow better. Carotid MRA was performed on ten healthy volunteers and six patients, on a 1.5 T system. A special adapter was constructed to use with 3-inch (receive-only) coils, which were placed over the carotid bifurcations. Routine anterior neck coils were also used. Contiguous axial two-dimensional (45/8.7, 1.5 mm, flip angle 60 °) time-of-flight sequences were used. Image matrix was 256 × 256 with two signals averaged and acquisition time 6–10 min. These images were postprocessed and reformatted into angiographic views using a maximum intensity projection algorithm. Computer simulation of carotid artery blood flow throughout the cardiac cycle based on vessel contours derived from digital subtraction angiography was carried out by finite element analysis. Improved definition of vessel margin, particularly at the carotid bifurcation, and substantially increased signal-to-background ratio of flowing blood were obtained with 3-inchcoils. Apparent loss of signal in the carotid bulb was diminished. In one patient, contiguous flow throughout a high-grade stenosis was well defined, with the surface coil method, while drop-off of signal was observed with routine neck coil imaging.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...