Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Acta neuropathologica 78 (1989), S. 472-483 
    ISSN: 1432-0533
    Keywords: Astroblastoma ; Electron microscopy ; Immunohistochemistry ; Organ culture ; Tanycytes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Two examples of cerebral astroblastoma have been studied by electron microscopy and immunohistochemistry, one of them having been maintained in vitro in an organ-culture matrix system for 8 months and the explants studied by light and electron microscopy at different time intervals. The fine structural characteristics were those of a glial cell type with features intermediary between those of astrocytes and ependymocytes. They recapitulated the structure of the tanycyte, a glial precursor cell which is normally found scattered along the ependymal lining of the embryonal and neonatal mammalian brain, but is distinct from epithelial ependymocytes. The possible origin of some astroblastomas from such a cell would account for a number of characteristics in this enigmatic type of glioma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2161
    Keywords: Key words Magnetic resonance (MR) ; Cartilage ; MR ; MR ; low-field-strength imaging ; MR ; three-dimensional ; MR ; fat-suppression
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract  Objective. To identify an optimal pulse sequence for in vitro imaging of hyaline cartilage at 0.5 T. Materials and methods. Twelve holes of varying diameter and depth were drilled in cartilage of two pig knees. These were submerged in saline and scanned with a 0.5-T MR system. Sixteen T1-weighted gradient echo (GE), two T2-weighted GE, and 16 fast spin echo sequences were used, by varying repetition time (TR), echo time (TE), flip angle (FA), echo train length, profile order, and by use of fat saturation. Contrast-to-noise ratios (CNR) of cartilage versus saline solution and cartilage versus subchondral bone were measured. Cartilaginous lesions were evaluated separately by three independent observers. Interobserver variability and correlation between the quantitative and qualitative analyses were calculated. Results. The mean CNRs of two specimens of cartilage versus saline solution ranged from 6.3 (±2.1) to 27.7 (±2.5), and those of cartilage versus subchondral bone from 0.3 (±0.2) to 22.5 (±1.4). The highest CNR was obtained with a T1-weighted spoiled 3D-GE technique (TR 65 ms, TE 11.5 ms, FA 45°). The number of lesions observed per sequence varied from 35 to 69. Observer agreement was fair to good. The T1-weighted spoiled GE sequences with a TR of 65 ms, TE of 11.5 ms and FA of 30° and 45° were significantly superior to the other 34 sequences in the qualitative analysis. Conclusion. T1-weighted spoiled 3D-GE sequences with a TR of 65 ms, a TE of 11.5 ms, and a FA of 30–45° were found to be optimal for in vitro imaging of cartilage at 0.5 T.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...