Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Experimental brain research 12 (1971), S. 184-203 
    ISSN: 1432-1106
    Keywords: Lateral geniculate ; Cat ; Synapse
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The laminae near the optic tract which have previously been described as C, C1 and C2, have been studied electron microscopically and compared ] to the A laminae. In the A laminae most of the presumed retinogeniculate axons end in encapsulated synaptic zones that contain multiple interconnected synaptic profiles. Only a few of these axons form simple axodendritic synapses upon proximal dendritic segments of the largest cells. In the C laminae the situation is reversed. Most of the retinogeniculate axons end as simple synapses upon medium or small dendrites and few end in encapsulated synaptic zones. Further, these zones are simpler in the C laminae than in the A laminae. The neuronal profiles are smallest and the synaptic interconnections appear to be least complex in lamina C2, where there are only a few, small, presumed retinogeniculate terminals. Of the three C laminae, lamina C, furthest from the optic tract, shows the largest profiles and the most complex interconnections. Bundles of very fine axons occur in all the laminae, but they dominate the regions closest to the optic tract (lamina C2) where they tend to run parallel to the lamina. Some of the largest cells in laminae A, A1 and C are contacted by very fine perisomatic axons which contain round vesicles. These axons have not been described before and are likely to represent an input too fine to have been demonstrable by light microscopical methods.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1227-1233 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A combined magnetic sector-time-of-flight instrument has been constructed and used with both continuous (liquid secondary ion mass spectrometry and electrospray ionization) and pulsed (matrix-assisted laser desorption/ionization) ion sources. The design includes provision for both low- and high-energy gas collision induced decompositions and orthogonal acceleration of the product ions into the time-of-flight mass analyser. Tandem mass spectra may be acquired for singly and multiply charged precursor ions and reliable mass measurements are easily obtained. Product-ion mass spectra are quite reproducible regardless of any instability in the precursor ion beam intensity.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...