ISSN:
1572-8838
Schlagwort(e):
environmental remediation
;
first-order kinetics
;
mass transport
;
medium pH
Quelle:
Springer Online Journal Archives 1860-2000
Thema:
Chemie und Pharmazie
,
Elektrotechnik, Elektronik, Nachrichtentechnik
Notizen:
Abstract The galvanic reaction of metallic copper in Cr(VI)-laden aqueous solutions of varying pH was examined by in situ u.v.–visible spectrophotometry, rotating disc electrode chronopotentiometry and cyclic voltammetry. The galvanic reaction in 0.2 M H2SO4 solutions was pseudo first order in Cr(VI) concentration. Experiments with both magnetically stirred solutions and a copper mesh or a copper film in a rotating disc electrode configuration revealed the reaction to be diffusion-controlled with respect to Cr(VI) transport to the copper surface. Finally, cyclic voltammetry data in Cr(VI)-laden media of varying pH underline the important role of protons in the galvanic reaction.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1023/A:1004038909149
Permalink