Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 0392-6737
    Keywords: Photoluminescence ; Excitons and related phenomena ; Charge carriers: generation, recombination, lifetime and trapping
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Description / Table of Contents: Riassunto Si presenta, in questo lavoro, uno studio sperimentale degli effetti delle disomogeneità spaziali e temporali nei plasmi di elettroni e lacune generati da impulsi laser potenti in strutture a buche quantiche di GaAs/AlGaAs. Si trova che tali disomogeneità modificano fortemente gli spettri di fotoluminescenza e devono quindi essere considerate per una corretta interpretazione dei dati sperimentali. La forma di riga degli spettri di luminescenza viene analizzata mediante un modello statistico che include, in modo semplice, le disomogeneità spaziali e temporali degli impulsi laser usati per l’eccitazione. Si ottiene un accordo soddisfacente con i dati sperimentali e si trova che i valori dei parametri ottenuti dal fit dipendono in modo sensibile dal modello assunto per la descrizione delle disomogeneità. Grande cautela deve essere quindi usata nel dedurre le proprietà del plasma fotogenerato a partire da una analisi delle forme di riga.
    Notes: Summary The effects on the luminescence lineshape of the spatial and temporal inhomogeneities of the electron-hole plasma generated by strong laser pulses in GaAs/AlGaAs multiple quantum well structures are experimentally investigated. It is found that inhomogeneities strongly affect the luminescence spectra and must be taken into account for a correct interpretation of the experimental data. The lineshape of the luminescence spectra is analysed using a statistical model that includes, in a simple way, the spatial and temporal inhomogeneities of the laser pulses used for excitation. A fair agreement is obtained with the experimental data; at the same time the values of the fit parameters turn out to be rather sensitive to the model assumed for describing the inhomogeneities. Therefore, caution has to be used when inferring plasma properties, such as the carrier density and temperature, from a lineshape analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...