Values of total pressure drop are presented for the flow of vaporizing water in an internally heated 1-in. I.D. by 1½-in. O.D. annulus at mass velocities of 270 to 1,440, lb./(sec.)(sq.ft.), pressures of 9 to 180 lb./sq. in., and up to 0.34 fraction by weight vaporized. The total heated length over which boiling took place was as large as 6 ft. There is no evidence of “sonic” pressure jumps at the outlet. The results for the annulus mentioned lie within +30 to -11% of the Lockhart-Martinelli curve at higher qualities and with ±45% of the correlation at lower qualities where the actual quality is more uncertain. A simplified correlation in terms of quality and volume fraction of liquid predicted the two-phase frictional pressure drops with an average error of 41%.It was found that the ratio of the two-phase pressure drop through a 0.3-in. orifice to the drop with no vaporization was approximately a linear function of the quality in the vena contracta but was only one tenth to one third as great as would be predicted if the mixture were to expand as a homogeneous fluid. Prediction of orifice presure drops is improved if slip between vapor and liquid is considered.