Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1611-1613 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Using an energy balance approach incorporating a Flory-Huggins expression for free energy and the strain energy of the material, the solvent removal process in liquid-based coatings was shown to depend on stress and temperature. An equilibrium is obtained between residual solvent content and stress in the coating at a given temperature. Such stress-dependent solvent removal behavior was observed with a polyamic acid coating solution-cast using N-methylpyrrolidinone.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1107-1110 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The Poisson's ratios of polyamic acid and polyimide films were determined using a high pressure gas dilatometer. In this technique, a sample is held at constant length and a hydrostatic pressure is applied to the sample. The resulting change in stress on the sample with applied pressure provides a measure of Poisson's ratio. For fully cured polyimide films based on pyromellitic dianhydride and oxydianiline, Poisson's ratio was measured to be 0.34 at approximately 1% strain. This value increases to 0.48 as the strain is increased to 5%.
    Additional Material: 6 Ill.