Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Chemical excitation source ; Chemiluminescence detector ; Chemical band narrowing ; Dansyl derivative ; Serum
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A peroxyoxalate chemiluminescence detection system for liquid chromatography is described. The excitation of fluorophores is generated by the reaction of bis-(2,4,6-trichlorophenyl)oxalate or bis(2,4-dinitrophenyl)oxalate and hydrogen peroxide, which are added to the column effluent. The influence of the solvents and the concentrations of the reagents have been investigated. The influence of the flow cell volume on sensitivity and on band broadening have also been studied and a “chemical band narrowing effect” has been observed. Different types of apparatus have been compared for detection of the emitted light. The system has been used for the detection of the dansyl derivative of a drug with a secondary amine functional group in serum samples. The detection limits are in the 1–10pg range.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 11-14 
    ISSN: 0935-6304
    Keywords: Liquid chromatography ; Fluorescence ; Ion-pair extraction ; Amines ; Post-column reaction ; Auto-analyser ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A detection system is described which is based on fluorescent ion-pair formation between tertiary amine drugs and dimethoxyanthracene sulphonate. A dynamic micro-extraction principle is then used to isolate the ion-pairs from the excess reagent. The band broadening of this extraction detector was kept below 20% using standard auto-analyser equipment. With the enhanced selectivity and sensitivity of this approach it was possible to analyse chloropheniramine in urine at ppb concentrations using a pre-column clean-up trace enrichment step.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...