Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    ISSN: 0021-9304
    Schlagwort(e): bonding-strength ; shear-strength ; simulated body fluid ; push-out measurement ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: This study was undertaken to evaluate the effect of coating characteristics on the mechanical strengths of the plasma-sprayed HA-coated Ti-6Al-4V implant system both in vitro and in vivo. Two types of HA coatings (HACs) with quite different microstructures, concentrations of impurity-phases, and indices-of-crystallinity were used. In vitro testings were done by measuring the bonding-strength at the Ti-6Al-4V-HAC interface, with HACs that had and had not been immersed in a pH-buffered, serum-added simulated body fluid (SBF). The shear-strength at the HAC-bone interface was investigated in a canine transcortical femoral model after 12 and 24 weeks of implantation. The results showed a bonding degradation of approximately 32% or higher of the original strength after 4 weeks of immersion in SBF, and this predominantly depended on the constructed microstructure of the HACs. After the push-out measurements, it was demonstrated that the HACs with higher bonding-strength in vitro would correspondingly result in significantly higher shear-strength at each implant period in vivo. Nevertheless, there were no substantial histological variations between the two types of HACs evaluated. The most important point elucidated in this study was that, among coating characteristics, the microstructure was the key factor in influencing the mechanical stability of the HACs both in vitro and in vivo. As a consequence, a denser HAC was needed to ensure mechanical stability at both interfaces. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 37, 335-345, 1997.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 26 (1998), S. 984-994 
    ISSN: 0142-2421
    Schlagwort(e): ToF-SIMS ; SIMS ; metal ; contamination ; Si ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: Volumetric relative sensitivity factors (RSFs) are determined for 52Cr, 56Fe and 58Ni in an O2+-formed silicon oxide using a 12 keV Ga+ primary ion beam, and the influence of matrix oxygen content on these RSF values is evaluated. A multivariate expression for Si2+-referenced RSF values as a function of oxygen content is developed. This expression indicates that 12 keV Ga+ ion beam RSF values for 52Cr, 56Fe and 58Ni in O2+-formed oxide at 1.0 nm depth are in excellent agreement with well-established 8 keV O2+ RSF values in a silicon matrix. Because calculated RSF values for O2+-formed oxide at 1.0 nm depth and native silicon oxide are almost equivalent, time-of-flight (ToF) SIMS metal RSF values and detection limits in native oxide for a Ga+ liquid metal ion source are predicted, using the well-established 8 keV O2+ RSF values for metals in a silicon matrix. Time-of-flight SIMS silicon surface detection limits of 5×106 to 5×108 atoms cm-2 @ 0.5 nm are predicted for most metals of interest to the semiconductor community. © 1998 John Wiley & Sons, Ltd.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY : Wiley-Blackwell
    International Journal of Quantum Chemistry 62 (1997), S. 213-221 
    ISSN: 0020-7608
    Schlagwort(e): Chemistry ; Theoretical, Physical and Computational Chemistry
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Molecular orbital calculations of sixfold barriers in nitromethane, methyl boron difluoride, and trifluoronitromethane were performed by various Hartree-Fock and electron correlation methods. In those calculations, staggered and eclipsed conformations are of primary concern. These results indicated that for CH3NO2 and CH3BF2 the staggered conformations are more stable, while CF3NO2 has a more stable conformation in an eclipsed form. Both conformations do not differ significantly, which may account for the low internal rotational barrier of each molecule. Values of the barrier calculated by the Møller-Plesset perturbation and the quadratic configuration interaction methods did not match the experimental results. However, better internal rotational barrier values of each molecule were observed when the improved better basis sets and the Hartree-Fock method were selected. © 1997 John Wiley & Sons, Inc.
    Zusätzliches Material: 1 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...