Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 14 (1970), S. 2771-2784 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The relationship between spread height and upstream reservoir thickness, with power low coefficient as parameter, was obtained analytically. At all values of n studied, the value of r (ratio of spread height to nip width) increases with increasing values of H/ho where H is upstream reservoir thickness and ho is nip width. At higher values of H/ho, the curves of r, versus H/ho tend to “flatten” out, and r approaches an asymptotic value. For example, the asymptotic value of r for Newtonian fluids (power law constant of 1) is 1.226. Asymptotic values of r increase with decreasing values of the power law constant.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 19 (1975), S. 2351-2351 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 19 (1975), S. 2545-2562 
    ISSN: 0021-8995
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Maschinenbau , Physik
    Notizen: The fracture behavior of a piperidine/bisphenol A diglycidyl ether (A) resin has been determined in bulk and as an adhesive using the linear elastic fracture methods developed by Mostovoy1. The effect of adding carboxy-terminated butadiene-acrylonitrile (CTBN) elastomer to resin A was investigated. The opening-mode fracture energy () of resin A was 120 to 150 J/m2, and largely attributable to plastic deformation. Fractographic evidence was obtained for plastic flow at the crack tip during crack initiation. Propagation was unstable due to the rate dependence of the plasticity. There were no significant differences in the bulk and adhesive fracture behavior. Addition of 5-15% CTBN to resin A produced minute elastomer particles which increased to ∼4000J/m2 (at 15%). Further CTBN addition resulted in an elastomer-epoxy blend and a decrease in fracture energy. Fractography again indicated that crack initiation involved plastic deformation but that the elastomer had greatly increased the volume in which the deformation occurred. The adhesive fracture of the elastomer-epoxy was found to be strongly dependent on the crack-tip deformation zone size (ryc) in that was a maximum when bond thickness was equal to 2 ryc. At bond thicknesses less than 2 ryc, there was a restraint on the development of the plastic zone resulting in lower values.
    Zusätzliches Material: 13 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 13 (1979), S. 517-541 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: A series of poly(α-amino acid)s with controlled chemical variations were investigated in order to assess the effect of different chemical moieties upon arterial thrombosis. The gross implant surface properties ranged from hydrophobic to hydrophilic, ionic and nonionic. The materials were tested by implantation within canine femoral and carotid arteries. Results were compared with the response to the polyurethane Biomer.The changes in implant surface chemistry elicited a range of response that varied from intense thrombosis and rapid vessel occlusion to minimal thrombosis and endothelialization. The results showed that no simple relationship exists between a gross surface property, such as hydrophobicity, and the degree of thrombosis resistance. Some hydropobic and hydrophilic materials were found to have good thrombosis were shown to play and hydrophilic materials were found to have good thrombosis were shown to play an important role in both initial thrombosis and endothelialization. The major difference between materials that progressed to to rapid vessel occlusion and materials that remained patent was the degree of direct leukocyte adherence and spreading on the implant surface prior to extensive platelet aggregation (〈30 min). It was consistent for both hydrophobic and hydrophilic materials that the lack of direct leukocyte adherence to the implant surface was associated with intense thrombosis and rapid vessel occlusion. Conversely, the presence of numerous leukocytes directly adherent to either hydrophobic or hydrophilic surfaces appeared to have a moderating effect upon thrombosis and vessels with these implants remained patent. In instances when thrombosis was nonocclusive, the surfaces of the thrombi became endothelialized, primarily through the transformation of mononuclear leukocytes into endothelial cells. This article includes a hypothetical model representing the sequence of events and alternative pathways occurring at the blood-material interface, with special attention given to the involvement of leukocytes in arterial thrombosis.
    Zusätzliches Material: 13 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 5 (1971), S. 19-30 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Ideally, materials from which splints, braces, casts, and other orthopedic appliances are to be made should be capable of being shaped directly against the patient. They should be simple and quick to use, and require the minimum of special equipment. Appliances made from them should be dimensionally stable in service and acceptable to the patient in terms of comfort, weight, durability, and appearance.Synthetic trans-1,4 polyisoprene, prepared with a Ziegler catalyst system, is such a material. It crystallizes at temperatures below 130°F; it is a hard semi-rigid rubber at room temperature; and its compounds can be molded directly against the skin without discomfort. Laboratory tests show that molded shape and strength can be maintained even under stress at temperatures up to about 120°F, and service performance fully supports the results of laboratory testing.This paper describes the properties of trans-1,4 polyisoprene that make the polymer suitable for many orthopedic appliances, and includes examples of its uses in hospitals and rehabilitation institutions. Special attention is given to describing a recently developed technique for the making of artificial limb sockets using trans-1,4 Polyisoprene.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Organic Magnetic Resonance 5 (1973), S. A6 
    ISSN: 0030-4921
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 7 (1973), S. 781-783 
    ISSN: 0030-493X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Mass spectra of methoxycycloalkanes (CH3OR, R = C5 to C8) and of methoxymethoxycycloalkanes (CH3OCH2OR, R = C5 to C8, C12) have been compared with each other and with spectra of some steroidal analogues. It is concluded that the different fragmentation occurring in dimethoxymethane indicates decomposition before randomisation of excess energy.
    Zusätzliches Material: 2 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗