Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    Molecular and Cellular Endocrinology 56 (1988), S. 21-27 
    ISSN: 0303-7207
    Schlagwort(e): (Rat) ; Androgen ; Epidermal growth factor receptor ; Prostate, ventral
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie , Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Amsterdam : Elsevier
    Molecular and Cellular Endocrinology 84 (1992), S. 145-154 
    ISSN: 0303-7207
    Schlagwort(e): (Mouse) ; Androgen ; Nerve growth factor gene expression ; Submandibular gland ; Thyroid hormone
    Quelle: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Thema: Biologie , Medizin
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 1 (1955), S. 125-128 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: The characteristics of five Herschel-type Venturi tubes with throat diameters ranging from 0.073 to 0.359 in, and throat-to-pipe - diameter ratios from 0.0882 to 0.4340 have been investigated.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 4
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 9 (1963), S. 303-306 
    ISSN: 0001-1541
    Schlagwort(e): Chemistry ; Chemical Engineering
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: Existing theories on the effect of mass transport on the rate (uniformity) of chemical reaction within a porous solid assume that the reaction is of integer order. However the carbon-carbon-dioxide reaction has the kinetic rate form, rate = k1pCO2/(1 + k2pCO + k3pCO2). For conditions where the retarding effect of carbon monoxide is very pronounced, the buildup of small concentrations of carbon monoxide within the porous graphite can lead to appreciable nonuniformity of gasification. Thus the criteria normally used to predict uniformity of gasification break down. A numerical integration of the combined differential equation of mass transport and chemical reaction has been performed, with rate constants for the carbon-carbon dioxide reaction taken from the literature. The results indicate that extreme nonuniformity of reaction can exist even when the change in carbon dioxide concentration from the exterior of the sample to the interior is small. The results are similar to experimental determinations of non-uniformity of gasification, obtained by determining the porosity of reacted graphite samples as a function of depth from the reacting face. Experimentally nonuniformity of reaction was observed for gasification rates a hundredfold lower than the usual Thiele criteria would predict, probably because of carbon monoxide inhibition.
    Zusätzliches Material: 4 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 5
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 7 (1973), S. 327-342 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The two systems for artificial hip joints in use at present are metal-on-metal and metal-on-plastic. There are many variables affecting friction and wear, which include diameter, sphericity, relative geometry of the components, and surface roughness. Tests in a simulating machine incorporated cyclic load and motion. Frictional torque of metal-on-plastic joints increased with diameter; Charnley 22 mm diameter producing lowest friction. For metal-on-metal the contact situation produced variable results, but friction was higher than for the plastic joints. Reciprocating friction machine tests suggested that high molecular weight polyethylene and AP4 polyester gave low friction and wear. Vitallium gave at least three times the friction of the plastic using γ-globulin solution as lubricant; but wear appeared to be much less.
    Zusätzliches Material: 10 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 6
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 10 (1976), S. 61-76 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: Some of the mechanical properties of regrown canine tendons are compared to those of normal tendons of young and mature animals. Patellar and Achilles tendons from 12 beagle dogs were removed and studied with their bone origin and insertions. Mechanical tests were performed within 24 hr and test conditions simulated the physiological function of the tendon in vivo at room temperature. Specimens were soaked in Ringers solution and mounted in an Instron testing machine with load deflection curves plotted automatically. The parameters used for analysis were load extension, stress relaxation, elastic limit, and strain rate dependence.The regrown tendons in young animals appeared to quickly adjust in dimension and structure so that their properties were not significantly different from those of normal tendons on a load extension basis.The normal tendons were stiffer than regrown ones but the modulus of elasticity increased with age. The Achilles were stiffer than patellar tendons. Cyclic loading with 25 kg did not affect reconstructed tendon models, although some increase in stiffness was noted. The elastic modulus decreased with an increase in ambient temperature and increasing strain rate.
    Zusätzliches Material: 9 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 7
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 43 (1998), S. 162-167 
    ISSN: 0021-9304
    Schlagwort(e): guided bone regeneration ; expanded polytetrafluoroethylene (ePTFE) ; cyanoacrylate ; osteopromotion ; osseointegration ; Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: This study investigated the use of a prototype expanded polytetrafluoroethylene membrane attached to bone with butyl-cyanoacrylate, in facilitating guided bone regeneration into bone defects and around titanium screws in rabbit femora. Two experimental models were used to assess bone growth. The first model investigated two unicortical defects in each femora. The second was bone growth in a 500-μm engineered space around one transcortical titanium screw. In the first model there was a significant increase in bone formation at 1 and 2 months in the membrane groups (p 〈 0.01) as compared to the controls. In the second model the percentage of bone in contact with the implant was significant at 1 and 2 months in the defects covered with membrane compared to the uncovered defects. The uncovered defects had fibrous tissue adherent to the implant continuous with the overlying soft tissue. Our study demonstrated three points: this membrane can be used to increase bone regeneration into defects, this technique allows bone to grow directly around an implant, and butyl-cyanoacrylate can be used in deep soft tissue and bone applications without any apparent deleterious effects. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 43: 162-167, 1998
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 8
    Digitale Medien
    Digitale Medien
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 8 (1974), S. 245-260 
    ISSN: 0021-9304
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Medizin , Technik allgemein
    Notizen: The surface replacement hip prosthesis reported represents an attempt to improve upon some aspects of the present design of total hip. The prosthesis comprises a cap fitted over the femoral head and a liner fixed into the socket, both being cemented with methyl methacrylate. The chief advantage of this design is preservation of bone stock. The prostheses were inserted bilaterally into six dogs, and whilst ten joints failed, one case was strikingly successful at two years follow-up. It was concluded that the design showed sufficient advantages over current total hips and that there was sufficient possibility of success in some application, to merit further study.
    Zusätzliches Material: 11 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 9
    Digitale Medien
    Digitale Medien
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 17 (1991), S. 465-470 
    ISSN: 0142-2421
    Schlagwort(e): Chemistry ; Polymer and Materials Science
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Physik
    Notizen: It is shown that the exposure of organic coatings to high humidity or water immersion causes a rapid loss of adhesion. The use of organofunctional silanes of the general formula R1 - Si(OR)3, where R1 is an amino, epoxide, mercapto, methacryloxy or vinyl group, can materially improve the initial, wet and recovered adhesion of epoxide, urethane and alkyd coatings to mild steel and aluminium substrates when used as pretreatment primers and additives.XPS work on the locus of failure of surface coatings on aluminium substrates indicated that although some local loss of adhesion to the substrate may occur, the predominant mode of failure is cohesive within the paint film. These findings are discussed in the light of current theories.
    Zusätzliches Material: 9 Tab.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...