Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1435-1285
    Keywords: Schlüsselwörter Arteria thoracica interna-Bypass – Dopplersonographie – prä- und postoperative Diagnostik ; Key words Internal thoracic artery graft – Doppler ulltrasonography – pre- and postoperative diagnostic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Summary During the last 25 years the internal thoracic artery has become a well established conduit for coronary revascularization. Next to angiography, duplex-sonography is increasingly used as a non-invasive imaging procedure for the evaluation of this graft vessel. Preoperative investigation in 117 patients has yielded a high level of agreement between angiography and duplex-sonography. While the preoperative flow-pattern is dominated by systolic flow as it is typical for vessels supplying skeletal muscule, the postoperative findings show an adaptation to the coronary vascular bed as the diastolic flow increases. These non-invasive measurements are well matched with invasive intravascular recordings. Coronary angiography and duplex-sonography of the internal thoracic artery yielded comparable findings in respect to the procedural result. Considering the increasing use of the internal thoracic artery in coronary artery bypass surgery, this non-invasive method should gain increasing relevance.
    Notes: Zusammenfassung Die Verwendung der Arteria thoracica interna zur koronaren Revaskularisierung hat sich in den letzten 25 Jahren als Gefäß der Wahl etabliert. Neben dem etablierten Verfahren der Angiographie wird in den letzten Jahren die Duplexsonographie zunehmend als nicht invasives bildgebendes Verfahren zur Untersuchung dieses Gefäßes eingesetzt. Bei der präoperativen Evaluierung von 117 Patienten konnte im Vergleich zur Angiographie bei einem hohen Anteil der Patienten ein übereinstimmendes Untersuchungsergebnis festgestellt werden. Während in der präoperativen Phase das Strompulskurvenprofil entsprechend der arteriellen Versorgung eines Skelettmuskels durch einen hohen systolischen Anteil dominiert wird, kommt es zu einer postoperativen Anpassung an das koronararterielle Strombett in Form eines vermehrten diastolischen Flußanteils. Diese nicht invasiven Befunde der transthorakalen Duplexsonographie konnten durch invasive intravaskuläre Dopplermessungen bestätigt werden. Ebenso wie beim präoperativen Vergleich ergibt sich auch postoperativ ein hohes Maß an Übereinstimmung zwischen Angiographie und Duplexsonographie bei der Beurteilung des Revaskularisationsergebnisses. Im Hinblick auf die zunehmende Verwendung der Arteria thoracica interna als Bypassgefäß sollte dieses nicht invasive Verfahren zunehmend an Bedeutung gewinnen.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 539 (1986), S. 211-218 
    ISSN: 0044-2313
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: I.R.-Spectroscopic Investigation of the Interaction between Ni-containing Y-Zeolites and Carbon MonoxideBy the interaction of CO with reduced NiNaY or NiHY samples adsorbed CO on Ni2+ (2 215 cm-1) and on Ni+ (2 085 and 2 095 cm-1, respectively) and two species of adsorbed Ni(CO)4 are formed. Ni(CO)4 is produced in a slow, reversible reaction. Both species are in an equilibrium which is influenced by the acidity of the samples.
    Notes: Bei der Einwirkung von CO auf reduzierte NiNaY- und NiHY- Zeolithe beobachtet man adsorbiertes CO an Ni2+ (2 215 cm-1) und an Ni+ (2 085 bzw. 2 095 cm-1) sowie zwei Formen von adsorbiertem Ni(CO)4. Ni(CO)4 wird in einer langsamen, reversiblen Reaktion gebildet. Die beiden Formen stehen in einem durch die Acidität der Proben beeinflußten Gleichgewicht.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Berichte der deutschen chemischen Gesellschaft 56 (1923), S. 1619-1621 
    ISSN: 0365-9631
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...