Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 13 (1969), S. 2371-2381 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The viscosity-average molecular weight, Mv, of a polymer is given operationally through its limiting viscosity number [η] and the Mark-Houwink equation [η] = KMvα, where K and α are empirical constants. If [η] is measured under different conditions, α and Mv will vary for the same sample. Mvα is the α-order moment about the origin of the differential weight distribution of the polymer. Practically, the results of a series of Mv measurements on the same polymer are equivalent to a cluster of fractional moments of the weight distribution, with orders between 0.55 and 0.80. It is shown that the first moment of this distribution, Mw, may be estimated reliably by a straightline plot of Mv against α-extrapolated to α equals 1. This simple expedient is effective although there are probably no molecular weight distributions in which the relation is strictly linear and there are no mathematical distributions for which the αth root of the αth moment is a linear function of α for all α. The deviation from linearity is small enough, however, that the real curve can be represented by a straight line over a short range of α. Thus, Mw can be measured accurately, but Mn, Mz, or the breadth of the distribution is not accessible by this method. Experimental and literature examples show that the precision of Mw estimated by this method compares well with that of primary methods for measuring this molecular weight average. If a linear relationship is observed with reliable α values, this appears to be a sufficient condition for estimation of a valid Mw.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 39 (1998), S. 453-457 
    ISSN: 0021-9304
    Keywords: sclera ; collagen ; piezoelectricity ; dehydration ; sample orientation ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: The piezoelectric coefficients (d31) for a number of bovine and human scleral collagen samples were determined as a function of drying time at room temperature. The measured values of d31 decreased with drying time. There were significant differences in the values of the d-coefficient between the human and bovine eyes as well as in the values obtained from different regions of the eye. © 1998 John Wiley & Sons, Inc. J Biomed Mater Res, 39, 453-457, 1998.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...