Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 383-387 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Wide bore glass capillary ; Fused-silica capillary ; Component discrimination ; Butt connectors ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described in which a wide bore capillary column is used as an alternative to the more traditional packed column for the quantitative analysis of amino acids as their N-heptafluorobutyryl isobutyl ester (HBB) derivatives. The column, installed in a gas chromatograph previously configured for use with a packed column, is shown to give good reproducibility by repeated determination of amino acid response factors (RSD values for all amino acids are below 3%). A number of problems, encountered during the use of this column, are discussed and suitable techniques to overcome them are reported.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 11 (1988), S. 229-233 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused-silica capillary ; Wide bore glass capillary ; Packed column ; Plasma amino acids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficients of variation for all amino acids (with the exception of aspartic acid) were better than 11% with recoveries ranging from 81% to 122%. The data are compared with the corresponding results obtained using a packed column and show significant differences (p 〈 0.005) between values for glycine, serine, isoleucine, proline, methionine, aspartic acid, phenylalanine, and lysine. A similar comparison between results from the wide bore and the fused-silica open tubular (FSOT) column shows better agreement. Adjustment of chromatographic conditions for the wide bore analysis yields results in good agreement with those from FSOT analysis but which still differe significantly from the backed column data.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 234-238 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Packed column ; Wide bore column ; Fused silica column ; Amino acids ; Cerebrospinal fluid (CSF) ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: In the present study, the use of gas chromatography (GC) for the determination of amino acids in human cerebrospinal fluid (CSF) is described. Although some amino acids may be determined using a packed column following the removal of glucose, the major interfering component, the inadequate resolution of other amino acids from remaining unidentified components results in poor quantitation. The use of wide bore columns improves reproducibility considerably, but still it does not provide sufficient resolution to enable quantitative determination of all amino acids in human CSF. Good reproducibility data, with CV values for all amino acids of 7% or less and recoveries generally between 80% and 100%, can only be obtained using the fused silica open tubular (FSOT) column. Normal amino acid levels are presented for 10 samples of human CSF, which compare well with data previously reported in the literature.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 437-441 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica column ; Amino acids ; Urine ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: This report describes a convenient means of reducing the complex matrix which is responsible for interference during gas chromatographic determination of amino acids in urine. The pre-chromatographic clean-up employs the principle of solid phase extraction using bonded silica incorporating cation exchange groups. This approach avoids the detrimental effects on amino acid recoveries associated with resin-based cation exchangers. In spite of significant reduction in the complexity of chromatograms, only the high efficiency and resolving power offered by the analytical capillary column (e. g. fused silica open tubular, FSOT) is sufficient for quantitative and analysis of amino acids in urine. Reproducibility data from the complete procedure are determined, coefficients of variation (CV) for most amino acids being better than 5% with a mean recovery of 96%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 509-516 
    ISSN: 0935-6304
    Keywords: Ion exchange chromatography ; HPLC ; GC ; Quantitation ; Amino acids ; Physiological fluids ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Methodologies for quantitative analysis of amino acids in physiological fluids based on classical ion exchange, high performance liquid chromatography, and gas chromatography are analyzed. As judged by the relative number of reports on these techniques, it appears that classical ion exchange continues to be the main method of choice for amino acid determinations and only limited advantage has been taken of the benefits (e.g. lower capital outlay and running costs and shorter analysis times) offered by other techniques. More importantly, however, there appears to be insufficient quantitative evaluation of the methodologies used. As a result, the validity of many reports based on data from amino acid analysis of physiological samples may be questioned.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 555-560 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused-silica ; Plasma amino acid analysis ; “On-column” injection ; Classical ion exchange ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A capillary chromatographic procedure using a fused silica column is described which can be used to quantitatively determine amino acids in plasma following the pre-chromatographic “clean-up” described in a recent paper [1]. In substituting this procedure for that involving a packed column, advantage has been taken of the greater resolving power to separate amino acids from background component peaks. In order to extend this advantage and provide a sound basis for quantitative analysis, the technique of cold on-column injection was employed. As a result, good precision of standard analysis was obtained with relative standard deviation (RSD) values for all amino acids of less than 4%. Application of the entire procedure to plasma samples yields RSD values of better than 10% for all amino acids with recoveries ranging from 72% to 104%. Simultaneous determination of plasma amino acid levels by gas chromatography (GC) using capillary columns and by classical ion exchange (CIE) showed reasonable agreement. Statistical evaluation showed no significant difference between twelve amino acids. Values for the remaining two, namely, phenylalanine and histidine are significantly different (p 〈 0.005). Comparison of the values obtained from GC capillary and packed columns reveals no significant difference between fourteen amino acids. Significant differences exist between results for phenylalanine and tyrosine (p 〈 0.001). It is concluded that there is good agreement between data obtained by GC capillary and CIE techniques and that differences between results for phenylalanine and histidine are method related.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 14 (1991), S. 579-583 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Cold on-column injection ; Amino acid analysis ; Liver ; Brain ; Rat ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A procedure is described for the quantitative determination of amino acids in hepatic and brain tissue samples from the rat. Because the presence of certain matrix components in the tissue material led to interference with chromatographic analysis they were removed by a prechromatographic “clean-up” step.Quantitative analysis of amino acids, as their N-heptafluorobutyryl iso-butyl ester derivatives, was achieved by high resolution gas chromatography on an apolar fused silica open tubular column. Reproducibility data from the complete procedure are presented; coefficients of variation for arginine and histidine in hepatic tissue varied between 7.1 and 10.1% whereas those for most other amino acids were better than 5%, with a mean recovery of 90%.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...