Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 50 (1996), S. 562-567 
    ISSN: 0006-3592
    Keywords: tissue engineering ; synthetic biodegradable matrix ; polyglycolic acid ; polylactic acid ; endothelial cell ; heart valve ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Tissue engineered lamb heart valve leaflets (N - 3) were constructed by repeatedly seeding a concentrated suspension of autologous myofibroblasts onto a biodegradable synthetic polymeric scaffold composed of fibers made from polyglycolic acid and polylactic acid. Over a 2-week period the cells attached to the polymer fibers, multiplied, and formed a tissue core in the shape of the matrix. The tissue core was seeded with autologous large-vessel endothelial cells that formed a monolayer which coated the outer surface of the leaflet. The tissue engineered leaflets were surgically implanted in place of the right posterior pulmonary valve leaflet of the donor lamb while on cardiopulmonary bypass. Pulmonary valve function was evaluated by two-dimensional echocardiography with color Doppler which demonstrated valve function without evidence of stenosis and with only trivial regurgitation under normal physiologic conditions. Histologically, the tissue engineered heart valve leaflets resembled native valve leaflet tissue. © 1996 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 38 (1991), S. 557-560 
    ISSN: 0006-3592
    Keywords: levan ; continuous culture ; molecular weight ; Erwinia herbicola ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The optimal production of the fructan biopolymer levan by the bacterium Erwinia herbicola was investigated, including variations in nitrogen, carbon and phosphorous sources, pH, incubation time, culture yields up to 19% by weight produced based on conversion of sucrose as the carbon source when grown in a continuous culture system and processed by tangential flow filtration. Product identity was confirmed with gas chromatography (GC) and 13C nuclear magnetic resonance (NMR). Gel permeation chromatography (GPC) and low-angle laser light scattering (LALLS) determination of the molecular weight of the product showed a significant difference in molecular weight values dependent on the method of analysis. Analysis by GPC resulted in molecular weight one order of magnitude lower than LALLS independent of sample, underscoring the unusual nature of this biopolymer.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 20 (1993), S. 309-316 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The quantification of oxygen and carbon in high-temperature (Tc) superconducting oxide thin films was made by employing elastic resonance in He backscattering analysis. A method combining the oxygen resonance technique and channeling was presented for measuring the nature of the oxygen disorder near the surface and the interface in a YBCO superconducting film grown on an MgO substrate. The oxygen resonance technique was used to quantify the oxygen profiling in the metal/YBCO contacts, showing that Zr and Nb act as sinks to oxygen from YBCO films and are oxidized in the forms Zr/ZrO2/YBCO/MgO and Nb0.2/YBCO/MgO after annealing in a vacuum at 350°C. We combined the carbon and oxygen resonances to determine the carbon contamination and oxygen concentration changes on the YBCO surface after coating and baking the photoresist. Residual carbon on the surface and a thin layer of oxygen depletion near the YBCO surface have been observed. The residual carbon in Bi2Sr2CaCu2O8 films made by the decomposition of metallo-organic precursors was quantified using carbon resonance.
    Additional Material: 15 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemie Ingenieur Technik - CIT 70 (1998), S. 1198-1198 
    ISSN: 0009-286X
    Keywords: Chemistry ; Industrial Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 36 (1998), S. 1217-1226 
    ISSN: 0887-624X
    Keywords: polypropylene ; pyrene ; two-solute system ; pulse radiolysis ; solute ionic species ; solute excited states ; low-temperature radiolysis ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A pulse radiolysis study of isotactic polypropylene (PP) film has been carried out with the main aims of investigating charge trapping in an undoped system and solute radical ion generation in an pyrene (Py) doped matrix. In PP, pulse radiolysis gives electron-positive hole pairs. The electron can be stabilized in the undoped system as a trapped electron, et-. The transient absorption spectrum of et- in the near-IR (up to 1800 nm) was observed in the temperature range 30-100 K. This IR absorption was not detected in the case of oxidized PP. In such a matrix electrons can be scavenged by oxidation products generating respective radical-anions (absorption in the UV RANGE, λ 〈 350 nm). In a doped matrix transient absorption bands centered at 450 and 500 nm were observed which can be assigned to the Py radical cation and anion, respectively. The recombination of these ionic species leads to monomer excited-state formation observed during and after the 17 ns pulse. Contrary to the Py-doped polyethylene no excimer emission was detected at room temperature even if Py content in PP was close to 0.02 mol dm-3. The rate of Py radical-ion decay was found to be temperature dependent. Two linear parts of the Arrhenius plot were observed which intersected at ca. 240 K, the glass transition temperature, Tg, for PP. The activation energies calculated for two parts of Arrhenius plot were equal to 111 and ca. 0.78 kJ mol-1 for T 〉 Tg and T 〈 Tg, respectively. Some preliminary results concerning the ionic processes in PP containing two solutes (Py, 3,3′-dimethyldiphenyl) were presented. The mechanism of ionic recombination in PP will be proposed and discussed. © 1998 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 36: 1217-1226, 1998
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 35 (1997), S. 299-305 
    ISSN: 0887-624X
    Keywords: poly(methylmethacrylate) ; pulse radiolysis ; charge scavenging ; doped polymers ; excited states ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The spectra of transients produced in pulse-irradiated pure poly(methyl methacrylate), PMMA, at room and ∼ 130 K temperatures were measured. The intermediates were identified as PMMA radicals and radical anions. In the pulse-irradiated PMMA-pyrene (Py) system the solute excited states and radical ions were produced. Scavenging of negative charges by Py was directly observed at 130 K in a µs time scale. Py fluorescence was found to be produced mainly as a result of Čerenkov photoexcitation. At room temperature, some contribution of ionic mechanism to Py fluorescence formation was found. © 1997 John Wiley & Sons, Inc.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 30 (1992), S. 2187-2193 
    ISSN: 0887-624X
    Keywords: chitin ; chitosan ; fibers ; crosslinking ; epichlorohydrin ; film ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A need exists for the development of totally biodegradable packaging materials. Chitosan is an under-utilized polymer which possesses many of the desired characteristics for this application. This article describes the crosslinking of chitosan fibers. Epichlorohydrin (ECH) was selected as a convenient base catalyzed crosslinking agent. The strength of chitosan fibers, especially wet tenacity, is improved by crosslinking. © 1992 John Wiley & Sons, Inc.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part A: Polymer Chemistry 36 (1998), S. 1209-1215 
    ISSN: 0887-624X
    Keywords: poly(methyl methacrylate) ; pyrene ; pulse radiolysis ; radical ion decay ; ion recombination ; fluorescence ; Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A pulse radiolysis study of poly(methyl methacrylate) in the presence of pyrene has been carried out in the temperature range 100-295 K. The concentration of pyrene was changed from 10-3 to 10-1 mol dm-3. The absorption/emission spectra and kinetics of solute excited states and solute radical ions were investigated. It was found that pyrene excited states were formed as a result of their radical ion recombination in a time scale up to seconds. The decay of solute radical ions was influenced by photobleaching and can be described by a time-dependent rate constant. The activation energy of Py ions decay was temperature dependent and was equal to 35.7 and 1.2 kJ/mol for temperatures 〉Tγ and 〈Tγ, respectively, where Tγ ∼ 175 K represented the transition temperature responsible for γ-relaxation. The reaction mechanism was proposed. © 1998 John Wiley & Sons, Inc. J Polym Sci A: Polym Chem 36: 1209-1215, 1998
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 26 (1986), S. 338-345 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Dynamic dielectric analysis (DDA) has been used to study curing polymer systems and thermoplastics. Measurements have been made over a frequency range of six decades. This wide range of frequencies increases the amount of information which can be obtained. The data is analyzed in terms of the frequency dependence of the complex permittivity ε*, specific conductivity σ(ohm-1 cm-1), and the relaxation time τ, parameters which are characteristic of the cure state of the material and independent of the size of the sample. Dynamic dielectric measurements have been used to monitor polymer processing in UDEL-P1700, LARC-160, polyphenyl quinoxaline (PPQ), and Epon 828 cured with Agent U. Dynamic dielectric measurements have been correlated with viscosity for the polysulfone thermoplastic UDEL-P1700 and with viscosity and ultrasonic measurements on the DGEBA type epoxy Epon 828 cured with Agent U. The experimental results suggest that when ionic processes dominate the dielectric response, the intensive property σ is a good monitor of the resin's viscosity. The results show that the dielectric relaxation time τ can be used to monitor the state of the system and the extent and rate of the reaction. Solvent evolution can also be easily observed.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Bognor Regis [u.a.] : Wiley-Blackwell
    Journal of Polymer Science Part B: Polymer Physics 24 (1986), S. 263-277 
    ISSN: 0887-6266
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Notes: Rutherford backscattering spectrometry with a 2.1-meV He2+ion beam is used to measure the diffusion of iodine into polyamic acid and polyimide films. The iodine diffusion coefficient D decreases from its initial value of about 2X10-13cm2/s in polyamic acid to approximately 1.4 × 10-15cm2/s in partially cured polyimide, but then increases to a value of nearly 1.5 × 10-14 cm2/s in fully cured polyimide. This dramatic increase in D cannot be attributed to the “in-plane” biaxial orientation of the polyimide molecules since indential D's were found with isotropic specimens. Microvoids less than 2 nm in size caused by water and carbon dioxide formation during imidization may, however, give rise to the observed behavior. The results demonstrate that Rutherford backscattering spectrometry with its excellent depth resolution (better than 30 nm) and good sensitivity (50 ppm iodine can be detected) is very useful for measuring the diffusion of slowly diffusing species in glassy polymers.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...