Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 20 (1980), S. 1097-1101 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Three front runners for the next generation of devices for fine line lithography are photo, electron, and X-ray lithography. Each of these techniques has both advantages and disadvantages when considered for direct wafer processing. This paper discusses the problems encountered using each of these techniques and how a trilevel technique can be applied to make each of these techniques more viable.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 20 (1986), S. 65-77 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Implant stabilization by biologic ingrowth into a porous surface offers a durable method of prosthetic fixation. These systems, however, lack the immediate stability offered by the use of acrylic bone cement. The interface strength of porous coated Co—Cr—Mo in a canine model does not approach that of acrylic bone cement until two weeks postoperatively. It is expected that this would be a minimum time period in clinical applications. Both chemical and electrical means have been advocated as methods to affect tissue ingrowth. A study using a canine model was undertaken to determine tissue ingrowth rates utilizing examples of these two methods: (1) impregnation of the porous structures with tricalcium phosphate powder (TCP); or (2) the application of an electrical stimulator to the implant with the implant itself serving as the cathode. Ten implants were coated with TCP, two each at weekly intervals from 1 to 5 weeks. Plain porous rods were likewise implanted, serving as the controls. While histology did reveal a slightly more dense bony structure, the interface bond strength was not affected by TCP. Electrical stimulation of the implant was similarly investigated with an additional time period of 10 weeks. Compared to the controls, the electrically stimulated implants reveal no statistically demonstratable difference in interface strength. Histologic specimens indicate larger areas of calcification than are observed in the controls.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    Journal of Biomedical Materials Research 18 (1984), S. 631-641 
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Clinical and in vitro studies have implicated dietary components as major aetiological factors in staining of teeth and acrylic materials associated with chlorhexidine use, a local side effect not unique to this antiseptic. These experiments studied the precipitation and surface staining reactions of the cationic antiseptics alexidine, cetyl pyridinium chloride (CPC), chlorhexidine, and hexetidine, with the beverage tea. All of the antiseptics precipitated a standard tea solution and for alexidine and chlorhexidine acetate and gluconate, this was at concentrations 〉100 μmol/L, for hexetidine 〉200 μmol/L, and for CPC 〉400 μmol/L. With the exception of CPC precipitation was reduced with decreasing pH and for chlorhexidine was inhibited below pH 3. The addition of polymethylmethacrylate (PMMA) to the antiseptic solutions increased the precipitation concentrations by an amount calculated to be adsorbed by polymer. Acrylic blocks treated with equimolar solutions of the antiseptics became progressively and significantly more stained by tea than control specimens over a 5-day period. Alexidine induced significantly greater staining and hexetidine significantly less than the other antiseptics. Staining was pH dependent and significantly reduced as the pH decreased. Both stain and precipitates were insoluble in strong acids and alkalis. It is concluded that staining observed clinically may represent a precipitation reaction with the complexing of antiseptics with dietary chromogenic material.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...