Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 31 (1985), S. 473-482 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Rates of mass and momentum transport in narrow flow channels (gaps 0.2-0.5 mm) have been determined over a wide range of flow velocities, 220-7,700 cm/sec (Re 1,300 to 22,000). Existing correlations that apply to smooth channels of much larger hydraulic diameter were found to be valid for the narrow channels as well. However, in the turbulent regime the condition of hydraulic smoothness could be satisfied only when the walls were optically smooth. Transport rates to rough walls were also measured. The ratio of the mass transport to the momentum transport in the form of jD/(f/2) - a measure of the improved mass transfer compared to the increased pressure drop - is given for the smooth and rough-wall cells over the Re range studied.
    Additional Material: 12 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 34 (1988), S. 519-523 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Chemical Engineering & Technology - CET 20 (1997), S. 469-474 
    ISSN: 0930-7516
    Keywords: Chemistry ; Industrial Chemistry and Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Bubble columns are commonly used in industry for polluted gas treatment. Based on the same principle, the droplet column which is not widely known in the literature, uses much higher gas velocities, up to 14 m/s. This study concerns the hydrodynamics and mass transfer in this apparatus, in presence or absence of solid particles. Our results have demonstrated the impact of dusts on mass transfer performance giving rise to an increase in the kL aL coefficient with decreasing particle size. However, no influence of dust on the hydrodynamics of the column has been demonstrated within the studied particle size range.A study of liquid holdups obtained by three different methods is also carried out. Our results are comparable, thus validating the methods used.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 10 (1966), S. 1285-1294 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: High quality packaging films from hydroxyethyl cellulose of low degree of substitution (DS) are being produced commercially in this country and abroad. Increasing demand for this and a variety of other applications requires a rapid and simple production control method for determining hydroxyethyl substitution of cellulose. None of the known analytical methods fulfills these requirements. The present paper describes a method which is based on the relationship between the solubility and the molar hydroxyethyl substitution of hydroxyethyl cellulose. A washed and dried sample of hydroxyethyl cellulose is dissolved in 7% aqueous sodium hydroxide. Methyl alcohol, a nonsolvent, is used to precipitate a fraction of the sample. The turbidity of the equilibrium system is determined and optical density readings are related to molar substitution. The method is most useful in low DS ranges of 2-8% EtO but is susceptile to broader application through adjustment of the composition of the solvent-nonsolvent mixture. Relatively large variations in DP can be tolerated. The molar substitution level of an hydroxyethyl cellulose sample can be obtained in 40 min. by this method, making it a practical production control technique.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 229 (1936), S. 300-304 
    ISSN: 0863-1786
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Das basische Bariumchlorat bildet in wäßriger Lösung keine komplexen Bariumkationen im Sinne von E. HAYEK, sondern ist überwiegend nach folgendem Schema in Ionen gespalten: \documentclass{article}\pagestyle{empty}\begin{document}$$ {\rm Ba(OH)ClO}_{\rm 4} \to {\rm Ba}^{ \cdot \cdot } + {\rm OH'} + {\rm ClO'}_{\rm 4} $$\end{document} wie aus Überführungsmessungen, Bestimmungen der Gefrierpunktsdepression und der Hydroxyl-Ionenkonzentration geschlossen werden muß. In konzentrierteren Lösungen erfolgt die elektrolytische Dissoziation in geringem Maße stufenweise nach: \documentclass{article}\pagestyle{empty}\begin{document}$$ {\rm Ba(OH)ClO}_{\rm 4} \to ({\rm BaOH)}^ \cdot + {\rm ClO'}_{\rm 4}. $$\end{document}.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Zeitschrift für anorganische Chemie 130 (1923), S. 173-180 
    ISSN: 0863-1786
    Keywords: Chemistry ; Inorganic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Until the present, analysis of aqueous solutions of atrazine has been conducted using a combination of liquid chromatography or gas chromatography with mass spectrometry, after a preconcentration step. We explore herein a new approach for studying support-phase-extracted atrazine and hydroxyatrazine samples. Solid-phase extraction membranes are inserted directly into the cell of a Fourier-transform mass spectrometer for analysis after laser ionization. It appears that atrazine and its metabolite have very different ionization processes. In the case of hydroxyatrazine, the [M + H]+ ion signal can be correlated to the concentration of the extracted solution. These encouraging results might open the route to a quantification method.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Chicester [u.a.] : Wiley-Blackwell
    Journal of Molecular Recognition 2 (1989), S. 63-74 
    ISSN: 0952-3499
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: A consensus sequence has been derived for vertebrate topoisomerase II cleavage of DNA (Spitzner, J. R. and Muller, M. T. (1988) Nucleic Acid. Res. 16, 5533-5556). An independent sample of 65 topoisomerase II sites (obtained in the absence of topoisomerase II inhibitors) was analyzed and found to match the consensus sequence as well as enzyme sites determined in the presence of the anti-tumor drug 4′-(9-acridinyl-amino)-methanesulfon-manisidide (m-AMSA). As originally described, conventional application of the consensus sequence afforded accuracy in the prediction of the locations but not the frequencies of topoisomerase II cleavages. In the present report, we describe a new method which quantitatively discriminates sites from nonsites, called the ‘matrix mean’ method (the mean match of a site to the matrix of base proportions from the original consensus sequence derivation). Furthermore, we derived a second method, called the ‘unique score’ model, which predicts frequency of topoisomerase II activity at a cleavage site. In the unique score method both DNA strands of a site are examined to determine the total number of the consensus positions that match on at least one strand of a potential site. From the new data base of 65 topoisomerase II sites, cleavages were scored for relative cleavage strength. Linear regression analysis showed a significant (p 〈 0.01) correlation between the unique score and cleavage strength. The study was extended to show that the unique score model accurately and quantitatively predicts topoisomerase II sites either in the absence or presence of m-AMSA using the same consensus sequence.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 2 (1988), S. 146-150 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The feasibility is reported of coupling a laser microprobe sampling system with a Fourier transform mass spectrometer (FTMS) for surface characterization. Analysis of an integrated circuit chip demonstrates capabilities for focusing the laser on a selected spot on a sample surface. Analysis of a model glass sample for which high resolution is required to separate metal ions from metal oxide ions emphasizes the advantages of coupling such a sampling system to an FTMS instrument.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 692-694 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Electrospray mass spectrometry has been applied to ionic inorganic systems such as heteropolyacids in methanol + water (1/1) or acetonitrile + water (1/1) solutions. Negative-ion mass spectra were obtained on four different heteropolyacids. Heteropolymolybdates H3PMo12O40 and H4PMo11VO40 and heteropolytungstates H3PW12O40 and H4SiW12O40 gave ions with different charges. H3PMo12O40 gave ions of m/z 1822, 912 and 608 which correspond respectively to [PMo12O403- + 2H+], [PMo12O403- + H+]2- and [PMo12O40]3- ions. Resolution of 1:2200 has demonstrated the charge of each ion acquired. Furthermore, the isotope distribution of the observed ions was in good agreement with theory. Thus, electrospray mass spectrometry has become a powerful soft ionization technique for the analysis of such ionic compounds, provided they are soluble and stable in the solvent system used.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...