Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 17 (1975), S. 129-142 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Rapid and extensive growth of Bacillus brevis ATCC 9999 was obtained in a complex medium containing yeast extract and peptone. Gramicidin S (GS) production in this medium reached 2.5 g/liter and 0.25 g/g dry cell weight. GS synthetase I production was also high in this complex medium. Chemically defined media were also developed for this strain. In a glycerol-ammonium sulfate-Tris-salts medium, the culture grew about 40% as well (rate and extent) as in complex medium. Although GS production was low (0.23 g GS/liter), peak specific activity of GS synthetase I was as high as on complex medium. Nutritional experiments showed that growth was stimulated by glutamine, methionine, proline, arginine, and histidine. Addition of these amino acids almost doubled the rate and extent of growth and GS production on a volumetric basis. However the increase in GS was due merely to the increased cell density; GS synthetase I specific activity was in fact decreased by the supplement. Complex medium is better than defined medium for GS and GS synthetase production due to increased cell density and a slower rate of synthetase disappearance.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    Surface and Interface Analysis 16 (1990), S. 183-187 
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: For the improvement of quantitative surface analysis using Auger electron spectroscopy (AES) we propose an Ni—Co alloy system as a candidate for a ‘primary reference material’ to be used for evaluating the accuracy of quantitative surface analysis. A Ni—Co alloy was chosen for two reasons. Firstly, the concentrations of the alloys (Ni49Co51,Ni75Co25) at the surface and in the near-surface region were found to be homogeneous, i.e. phenomena such as preferential sputtering and ion irradiation-induced surface segregation were no observed with angle-resolved XPS measurements during 1 keV Ar+ ion sputtering. Secondly, the corrections of matrix effects of Ni—Co alloys, such as the atomic density, the back-scattering factor and inelastic mean free path corrections, were calculated and found to be negligibly small.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Cell Biochemistry and Function 6 (1988), S. 263-269 
    ISSN: 0263-6484
    Keywords: Neutrophil ; granules ; heparin treatment ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Medicine
    Notes: Highly efficient methods for isolating two hydrolytic granules of neutrophils are described. Neutrophil obtained from guinea pig peritoneal exudate cells were washed extensively with isotonic sucrose and then treated with heparin. More than 95 per cent of the cells so treated were disrupted with a Dounce homogenizer. Since nuclei were broken, leaving other organelles intact, homogenates were incubated with DNase to reduce viscosity. Postnuclear supernatants were centrifuged on a discontinuous gradient of Percoll. Azurophil granules, high in β-glucuronidase activity, sedimented at fractions of d = 1·081 and showed very little activity of other marker enzymes. High neutral α-glucosidase activity was observed in granular fractions of d = 1·038 and it is suggested that this is a marker for specific granules of neutrophils.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kind of Au—Cu alloys (Au 75 at.-%-Cu 25 at.-%, Au 50 at.-%-Cu 50 at.-%, Au 25 at.-%-Cu 75 at.-%) were prepared, and these specimens, pure Au and pure Cu were distributed to the members of the VAMAS-SCA working group. The surface concentrations of these alloys were calculated from the Auger peak amplitudes in two ways. One method used the published relative sensitivity factors, and the other used pure Au and Pure Cu as the standard materials. The mean values of the surface concentrations calculated with the published relative sensitivity factors were almost the same as those calculated with the standard materials. This means that the published relative sensitivity factors are reliable to some extent. The error of the surface concentration calculated with pure Au and pure Cu as the standard materials lay between about 3% and 10%, and that with the relative sensitivity factors lay between about 7% and 20%. The calculated surface concentrations of Au were larger than the bulk concentrations of Au when the matrix effect was neglected.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    New York : Wiley-Blackwell
    Die Makromolekulare Chemie 54 (1962), S. 226-229 
    ISSN: 0025-116X
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Physics
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1124-1130 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: A new apparatus has been constructed in which ultrasonic velocity and attenuation coefficients can be measured under oscillatory deformation. Using this apparatus, dynamic ultrasonic parameters were obtained with sufficient accuracy to investigate plastic deformation directly. It is found that this method has potential as a new tool for the study of solid polymers during deformation.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Stamford, Conn. [u.a.] : Wiley-Blackwell
    Polymer Engineering and Science 29 (1989), S. 1131-1135 
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: It is proposed that dynamic density can be estimated from simultaneous measurements of ultrasonic velocity and modulus under an oscillatory deformation. An experimental investigation was carried out and a theoretical model applied. Preliminary experiments show that measurement of the dynamic density is a major aid to the study of plastic deformation.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 53 (1994), S. 1125-1127 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: The Japanese VAMAS-SCA working group is composed of 19 institutes. Three kinds of Au-Cu alloys (Au25 at%-Cu75 at%, Au50 at%-Cu50 at%, Au75 at%-Cu25 at%) were prepared, and these specimens were distributed to the members of Japanese VAMAS-SCA working group and Auger peak amplitude ratios were measured to clarify the correlation factor of different types of spectrometers. The comparison was carried out by using the relative sensitivity factor for Au and Cu. The relative sensitivity factor for lower energy varied from spectrometer to spectrometer, but that for higher energy did not vary so much. Therefore, to carry out the inter-laboratory comparison of the data, the transfer of the data of peak amplitude at higher energy should be recommended.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    ISSN: 0142-2421
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A matrix effect correction is required to improve the accuracy of quantitative AES analysis. The correction includes terms involving the atomic density (n), electron back-scattering factor (R) and electron escape depth (L). Many schemes have been proposed by various people for corrections of the R and L terms. However, up to now, there have been no systematic investigations of the correction accuracy of the proposed schemes. We have evaluated the correction accuracy, based on measured intensity data for Au—Cu alloys of different compositions. Comparison was made between the observed intensity ratio K (=Iunk/Istd) and the calculated intensity, ratio K′ (= C(nunk/nstd)(Runk/Rstd)(Lunk/Lstd)), where C and I represent the concentration and intensity, respectively. The superscripts ‘unk’ and ‘std’ denote that the parameters are for unknown and standard specimens, here the pure elements. If the correction works well, the error Er (= K′ — K)/(K) will become smaller. Evaluations were carried out on three schemes for the R correction and on seven schemes for the L correction using the Au 239 eV, Au 2024 eV and Cu 920 eV transitions. The root mean square (RMS) of the calculated errors showed several per cent for the best case and 20-30% for the worst case. The RMS error varied a few per cent between schemes for the R correction but it varied ∼30% for the L correction.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...