Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Electrophoresis 17 (1996), S. 1921-1924 
    ISSN: 0173-0835
    Schlagwort(e): Capillary zone electrophoresis ; Chiral separations ; Association constants ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A practical procedure is proposed for the determination of association constants and mobility of the associate of a solute with a chiral selector in chiral separations by capillary zone electrophoresis. The procedure is based on the measurement of the effective mobility of a solute at zero and two different nonzero concentrations of the chiral selector. Simple explicit formulas have been derived in order to calculate the required data. The essence of the procedure is that all mobility data are adjusted to the background electrolyte (BGE) without chiral selector, serving as the viscosity reference. A simple procedure is described for measuring the viscosity of the operational electrolytes directly with the commercial capillary electrophoresis instrumentation, and Walden's rule has been utilized for adjusting the experimental mobility data to constant reference viscosity. The use of the procedure is exemplified by a separation of D,L-tryptophan in BGE containing α-cyclodextrin as chiral selector.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 0173-0835
    Schlagwort(e): Antibiotics ; Chiral separations ; Enantiomers ; Drugs ; Herbicides ; Capillary electrophoresis ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A new glycopeptide antibiotic, MDL 63,246 (Hepta-tyr), of the teicoplanin family, has been evaluated in capillary electrophoresis for the resolution of chiral compounds of pharmaceutical and environmental interest. Electrophoretic separations were carried out in a polyacrylamide-coated capillary using the partial filling-counter current mode with aqueous-organic buffers in the pH range 4-6. Experimental parameters affecting resolution, such as antibiotic concentration, buffer pH, organic modifier type and capillary temperature, were studied. The Hepta-tyr antibiotic exhibited a high enantiorecognition capability towards the studied compounds at very low concentrations (1-2 mg/mL). The optimum experimental conditions were achieved by using a buffer at pH 5 containing acetonitrile at 25°C.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    ISSN: 0173-0835
    Schlagwort(e): Capillary zone electrophoresis ; Chiral separations ; Column-coupling system ; α-Hydroxycarboxylic acids ; Sensitivity of optical detection ; Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Chemie und Pharmazie
    Notizen: A new approach is described for highly sensitive chiral analyses by capillary zone electrophoresis, based on using an on-line combination of two capillaries filled with either chiral selective or achiral background electrolytes (BGE). Thus, the BGEs are selected in such a way that the first capillary provides optimum chiral selectivity and the second one optimum detection sensitivity. Direct chiral separations of enantiomers of mandelic, m-methoxymandelic, 3-phenyllactic and 3-indolelactic acids served as a model example for testing the approach proposed. The analyses were performed in a BGE containing acetate as a coion and L-OH-proline or aspartame as a chiral selector. For high sensitive analyses, an arrangement containing on-line combined chiral and achiral media were tested in one or two capillaries coupled via a bifurcation block. A detection limit as low as 10-18 moles was reached in the column-coupling system when the direct chiral separation was performed in the first capillary, filled with 20 mM acetate buffer, pH 4.4, containing 8 mM Cu (II) and 16 mM aspartame (L-aspartyl-L-phenylalanine methylester) and separated enantiomers were detected in the second capillary, filled with 20 mM acetate buffer, pH 3.1. The principle described is of general use in cases where the separation and detection of analytes in question require mutually different BGEs to reach the optimum selectivity and sensitivity, respectively.
    Zusätzliches Material: 8 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...