Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Column liquid chromatography  (2)
  • Anomalons  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Amsterdam : Elsevier
    Nuclear Tracks and Radiation Measurements (1982) 8 (1984), S. 563-566 
    ISSN: 0735-245X
    Keywords: Anomalons ; automatic track measurements ; nuclear collisions ; relativistic heavy ions
    Source: Elsevier Journal Backfiles on ScienceDirect 1907 - 2002
    Topics: Physics
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Vitamin B and C in tablets ; Experimental design ; Optimization of separation ; Multiple regression modeling
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The ion-pair liquid-chromatographic separation of the water-soluble vitamins thiamine mononitrate, riboflavin phosphate, nicotinamide, pyridoxine hydrochloride, ascorbic acid, saccharin, and the dye Sunset Yellow FCF (E110) has been examined for the analysis of the compounds in effervescent tablets. A Draper-Lin small composite design was used to study the impact on the compounds' retention times and peak-widths (the response variables) of four different mobile phase variables: percentage of methanol as organic modifier, the concentrations of hexanesulfonate as ion pairing reagent and of triethanolamine as competitive base, and pH. The interactions of these variables were also studied. The proposed design enabled derivation of multiple linear regression equations to model each compound's retention time and peak-width at half-height. The statistical reliability of the regression models was established by comparing predicted and experimental values. By introducing the regression models into a spreadsheet program (Excel 5.0), retention times and peak-widths for each compound were calculated at fixed mobile phase pH. The values of all the other combinations of the three mobile phase variables were changed in increments of two units within their examined boundaries, resulting in 225 different rows. For each combination the compounds' calculated retention times and their corresponding peak-widths were sorted in increasing order and the resolution between successive peaks was calculated. The minimum effective resolution (R s min) between each pair of peaks and the maximum retention time (t R max) in each row were then selected and used to construct contour plots indicating the location of zones of mobile phase parameter combinations whereR s min〉1.5 and the analysis was rugged, and wheret R max values were minimum. Their common regions resulted in optimum chromatographic separations. Examples are shown of chromatographic separations obtained using mobile phase combinations which were the best compromise of the three criteria selected.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Optimization ; Mixture design ; Special cubic polynomial model ; Pareto-optimality ; Overlapping resolution mapping (ORM)
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A systematic approach, using a mixture-design statistical technique, has been developed for selecting the optimum mobile phase for the separation of fat-soluble vitamins in reversed-phase high-performance liquid chromatography. A quaternary mixture of methanol, acetonitrile, tetrahydrofuran and water was used as mobile phase. Retention time and peak width were recorded in ten runs augmented with five replicates and the data were subsequently fitted to special cubic polynomial models. The resulting mathematical equations enabled prediction of resolution over the entire parameter space. Contour plots of minimum effective resolution and maximum retention time as a function of mobile phase composition are presented and discussed. Visual inspection of these plots provides an overview of the quality of the separation and the analysis time required for each possible mobile-phase composition with n the parameter space. It is demonstrated that the methodology followed was an important tool which enabled the taking of informed decisions necessary for selection of the optimum mobile phase for a chromatographic separation. A combination ofR S minimum andt R maximum as optimization criteria in a multicriteria decision-making plot using pareto-optimality concept is discussed. This combination enabled visual demonstration of the compromise between separation quality and the economics of analysis time. Our methodology has been compared with the common used technique of ‘overlapping resolution mapping’.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...