Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 21 (1983), S. 119-127 
    ISSN: 1741-0444
    Schlagwort(e): Compartmental models ; Control ; Least-squares fitting ; Muscle relaxants ; Parameter estimation ; Pharmacodynamics
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract To implement a feedback control system to achieve satisfactory muscle relaxation during surgical procedures, a mathematical formalism, based on linear compartmental theory, is derived to model the input/output response between the dosage of a drug administered and its neuromuscular effect as measured by the train-of-four (T4) ratio twitch response. The effect (T4 ratio) is related directly to the dosage schedule, and no attempt is made to include the plasma concentration of the neuromuscular blocking drug in the formalism. The neuromuscular blocking data of 24 patients, in whom the muscle relaxant d-tubocurarine (curare) was used, were fitted using a nonlinear least-squares data fitting routine. The number of compartments necessary to fit the data for each patient was determined using the general linear test. In all but three cases a biexponential model was sufficient to fit the data. Simulation studies also show that a biexponential model gives satisfactory control even for those patients for whom a triexponential model was necessary to fit the data. Further simulation shows that because of interindividual variation the application of adaptive control techniques will be needed.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    Biological Mass Spectrometry 10 (1983), S. 596-600 
    ISSN: 0306-042X
    Schlagwort(e): Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Two chemical ionization mass spectrometric methods were developed for direct determination of deuterium in water in the range of 0.0-0.6% 2H2O. One of them utilizes the batch inlet system, methane as the reagent gas, and the peak matching device of a magnetic sector mass spectrometer. The second one utilizes the directly-coupled gas chromatograph of a quadrupole mass spectrometer and computer control for ion selection and data processing. In this method the water itself serves as the reagent gas. The deuterium concentration is calculated from the ratio of ion intensities at m/z 20 (2HH2O+) and m/z 19 (H3O+). We have used these methods to determine total body water in 350 human subjects, which entailed making 900 measurements over a period of four years. Comparisons were made in 200 subjects of our results with those obtained by the creatinine method. No significant differences were found.
    Zusätzliches Material: 2 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...