Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1985-1989  (3)
  • Biochemistry and Biotechnology  (1)
  • Computed tomography  (1)
  • Electrogastrography
  • 1
    ISSN: 1432-1920
    Schlagwort(e): Arteriography ; Basilar artery diameter ; Computed tomography ; Vasospasm
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary In this study we have used a computed tomographic (CT) method using profile analysis to measure the diameter of the basilar artery. In a search for a noninvasive and repeatable method to substitute for the traditional arteriography in the evaluation of the degree of cerebral vasospasm, we employed both CT and arteriography to measure the diameter of the basilar artery in eight adult mongrel dogs weighing between 7 and 12 kg. In three of these animals, assessments were made before and after subarachnoid hemorrhage (SAH) induced by injecting autologous arterial blood into the cistern magna. It was found that the basilar artery diameter as evaluated by CT was 47% larger than that measured by arteriography. However, there was a very good correlation (n=63, r=0.75, p〈0.001) between the two methods. This paper presents a new model for the measurement of the basilar artery diameter, one which may also provide a safer method for the evaluation of vasospasm in humans.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 27 (1989), S. 538-542 
    ISSN: 1741-0444
    Schlagwort(e): Electrogastrography ; Gastric activity ; Phase shift
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract Electrogastric signals have been successfully measured both intraluminally and cutaneously. although it has been claimed by several researchers that the propagation direction of the electrogastric activities cannot be observed from cutaneous recordings, it is the aim of the paper to show that it is feasible. The reason why the propagation direction has never been observed from cutaneous recordings is that the reported methods for the abdominal measurements are not adequate. In the paper it is pointed out that the stomach should be localised before the measurement and the electrodes should be attached along the longitudinal axis of the stomach.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 3
    Digitale Medien
    Digitale Medien
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 27 (1985), S. 151-155 
    ISSN: 0006-3592
    Schlagwort(e): Chemistry ; Biochemistry and Biotechnology
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Biologie , Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
    Notizen: The physiological activity of microorganisms in environments with low dissolved oxygen concentrations often differs from the metabolic activity of the same cells growing under fully aerobic or anaerobic conditions. This article describes a laboratory-scale system for the control of dissolved oxygen at low levels while maintaining other parameters, such as agitator speed, gas flowrate, position of sparger outlet, and temperature at fixed values. Thus, it is possible to attribute in dilute nonviscous fermentations all physiologic changes solely to changes in dissolved oxygen. Experiments were conducted with Azotobacter vinelandii and Escherichia coli. Critical oxygen concentrations for growth (that value of oxygen allowing growth at 97% of μmax) were measured as 0.35 ± 0.03 mg/L for A. vinelandii and 0.12 ± 0.03 mg/L for E. coli. These values are significantly different from the commonly quoted values for critical oxygen concentrations based on respiration rates. Because of the superior dissolved oxygen control system and an improved experimental protocol preventing CO2 limitation, we believe that the values reported in this work more closely represent reality.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...