ISSN:
1432-1920
Keywords:
Key words Computed tomography
;
Contrast medium
;
Embolism
;
air
Source:
Springer Online Journal Archives 1860-2000
Topics:
Medicine
Notes:
Abstract We investigated the frequency of air bubbles in the subclavian (SCV) or internal jugular (IJV) vein in 200 patients who underwent contrast-enhanced CT of the head and neck. Half the patients were reviewed retrospectively (group 1), while the other half were investigated prospectively after the radiologists who administered the contrast medium were instructed to be careful not to inject even a single air bubble during the procedure (group 2). Air bubbles were observed in the SCV or IJV in 15 of the 100 patients in group 1, while in group 2, there were 4 such patients. Air injection, a common “complication”, can be reduced by care during the procedure.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/s002340050580
Permalink