  • Curie-point pyrolysis  (2)
  • 1
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Curie-point pyrolysis ; Multivariate analysis ; Sodium dodecylbenzene sulfonate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Multivariate analysis can be applied to quantitative analysis of sodium dodecylbenzene sulfonate (DBS) by pyrolysis gas chromatography. The pyrograms obtained from mixtures of DBS and polyoxyethylene lauryl ether (PEG) were normalized for the peak heights and areas of several internal standards which appeared in every pyrogram, against the characteristics peaks for DBS and PEG. This normalization method gave smaller experimental errors than when using one internal standard. The normalization values were used for cluster analysis unchanged. The values were calculated correlation coefficients and principal component analysis was performed using 11 data base and a set of sample data simultaneously. One calibration curve was calculated from the principal component scores. The DBS content of a sample was obtained from the calibration curve. Calculated values were in fair agreement with theoretical values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Curie-point pyrolysis ; Multivariate analysis ; Sodium dodecylbenzene sulfonate
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Multivariate analysis was used to develop a viable method for determination of sodium dodecylbenzene sulfonate (DBS) by Curie-point pyrolysis gas chromatography. The pyrograms obtained were normalized against a maximum peak area and peak height. Normalized values were used for Quantification IV, which is one of the multivariate analysis methods, to select useful values initially. Then cluster analysis was carried out using both the selected values and their deviations. This method corresponds to qualitative analysis and indicates which data-base is similar to the sample. On the basis of this data-base, calibration data-bases are chosen. Principal component analysis (PCA) was performed using the calibration data-base and a set of sample data simultaneously. The principal component scores and contribution coefficients obtained were used to construct a calibration curve from which the DBS content of the sample was calculated. The results are in fair agreement with theoretical values.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...