Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of dermatological research 292 (2000), S. 562-567 
    ISSN: 1432-069X
    Keywords: Keywords Vitamin B6 ; UVA ; Phototoxicity ; ESR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We have previously reported that pyridoxine shows UVA-induced cytotoxicity. Four other vitamin B6 compounds (pyridoxal, pyridoxamine, pyridoxal phosphate, and pyridoxamine phosphate) are metabolically more important in vivo than pyridoxine. These compounds were examined for UVA phototoxicity to cultured human fibroblasts. The cytotoxicity was measured by post-UVA irradiation colony-forming ability. All the B6 compounds except pyridoxal phosphate showed cytotoxicity. Pyridoxamine phosphate, which is the most important form of vitamin B6 in vivo, had the strongest cytotoxic effect. To examine the involvement of reactive oxygen species in the phototoxicity, we performed an electron spin resonance study using the spin trapping agent, 5,5-dimethyl-1-pyrroline N-oxide, and diethylenetriaminepentaacetic acid. We failed to detect radicals derived from vitamin B6. The cytotoxic effect remained in UVA-irradiated solutions for at least 30 min after the end of UVA irradiation. Hydrogen peroxide was produced in the solution, but the amount was not enough to cause cytotoxicity. In addition, the cells from xeroderma pigmentosum patients who belong to group A or C showed survival curves similar to those of normal fibroblasts. This suggests that cyclobutane pyrimidine dimers or 6-4 photoproducts of DNA were not involved in this damage. These findings suggest that UVA-induced vitamin B6 cytotoxicity is caused by toxic photoproducts resulting from irradiated vitamin B6.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 16 (1995), S. 293-305 
    ISSN: 1572-9559
    Keywords: gyrotron ; ESR ; wide frequency range
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The development of a high frequency electron spin resonance (ESR) spectrometer with a wide frequency range using a gyrotron as the radiation power source is described. GYROTRON FU-E, optimized for use in an ESR spectrometer in the millimeter wave range, was developed in Fukui University. In order to test the normal operation of the spectrometer, the ESR of two standard samples, single crystal and polycrystalline DPPH, has been measured, in the pulsed mode over the frequency range from 65 GHz to 135 GHz.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...