Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Comparative clinical pathology 4 (1994), S. 162-166 
    ISSN: 1433-2981
    Keywords: Electronic impedance ; Haematology analyser ; Multichannel analyser ; Veterinary
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Blood samples from 33 dogs, 28 cats, 24 horses and 25 cattle were analysed in duplicate on the Coulter Counter S-Plus IV and the Baker 9000 multichannel haematology analysers. The precisions of each instrument and the correlations between the instruments were evaluated. The precisions of both systems were good but, the Baker 9000 system showed more variability between duplicate determinations for all parameters. The Baker 9000 had better precision for white blood cell count, haemoglobin concentration, and MCV. Correlations between the two instruments were excellent except for MCHC. Neither analyser reliably provided feline platelet counts and the Baker 9000 also failed to report error messages for 8 of 10 apparently false platelet counts. The Coulter instrument consistently reported higher haemoglobin concentrations and higher feline and lower canine white blood cell counts than the Baker 9000.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 8 (1962), S. 18-25 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Data on pressure drop in two-phase, single-component fluid flow, both with and without heat transfer, are presented in terms of the Lockhart and Martinelli correlation parameters. The fluids used were trichloromonofluoromethane and hydrogen.The results are compared with the correlation curve recommended by Martinelli and Nelson and give frictional pressure drops that are about 40% lower than the curve. The reasons for the deviations are discussed in terms of the effects of friction factors, the existence of metastable equilibrium, accuracy of data and instrumentation, and calculation procedures.It is concluded that the Martinelli and Nelson correlation and a simple momentum pressure drop computation can be superposed to predict roughly the total pressure drop in tubes containing steady state, two-phase, single-component fluid flow with appreciable vaporization.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Blends containing polyethylene (LDPE, LLDPE, or LDPE-LLDPE) with different weight percent of styrene-isoprene-styrene (SIS) triblock copolymers have been obtained by extrusion-blowing. The morphology of the blends, investigated by scanning electron microcopy (SEM), has been related to composition but also to different parameters such as viscosity, nature of the polyethylene phase, and extrusion conditions. A large range of morphologies is observed and indicates that the main factors determining the morphology of the blends are the composition, the elongational fields at the exit of the die and, in certain limits, the relative viscosities of the components of the blends.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0032-3888
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The photo-oxidation of blends of low-density polyethylene and styrene-butadiene-styrene block copolymers has, been shown to result mainly from the degradation of the pollybutadiene part of the material. The solution infra-red and fluorescence spectra, and mechanical properties have been studied as a function of the irradiation time. Evidence of some interaction between the components of the blend could be obtained.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...