Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • 1990-1994  (2)
  • Embolization  (1)
  • Endovascular procedures  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    Neuroradiology 36 (1994), S. 144-147 
    ISSN: 1432-1920
    Schlagwort(e): Aneurysm ; Embolisation ; Endovascular procedures
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract We report the use of an N-butyl-2-cyanoacrylate (NBCA) mixture for embolisation of six cases of carotid aneurysm after detachable balloons, and/or microcoils had been placed in the aneurysm. The mixture was injected into the aneurysm to prevent delayed bleeding or distal migration of the balloons, or microcoils. No subarachnoid haemorrhage or distal migration of the balloons or microcoils occurred up to 4.5 years after embolisation. Reflux of the NBCA mixture into the parent artery occurred in one patient, who had a neurological deficit which recovered in a month. NBCA mixture may be useful in embolisation of intracranial or skull base arterial aneurysms, for reducing the size of remaining lumen in an aneurysm at high risk of rebleeding which accommodate no more balloons or microcoils, or preventing possible delayed migration of balloons or microcoils. However, prevention of leakage of the mixture into the parent artery remains a problem.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1920
    Schlagwort(e): Vertebral arteriovenous fistula ; Embolization ; Endovascular occlusion ; Detachable balloon ; CT
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Summary We report a case of vertebral arteriovenous fistula, in which embolization was complicated by migration of two coils and a partially inflated balloon. In order to relieve compression to the spinal cord, the displaced balloon was punctured percutaneously. For both relieving compression to the spinal cord and obliterating the residual fistula, the dislodged coils in the partially thrombosed epidural venous sinus were removed percutaneously and placed in the fistula, and more coils were implanted in the fistula percutaneously through the needle. CT follow-up half a year later showed complete resolution of compression of the spinal cord and complete recovery from myelopathy was clinically apparent.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...