Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-5233
    Keywords: Fasting plasma glucose ; Diabetes mellitus Epidemiology
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract In current clinical and research practice, the determination of diabetic status depends largely on plasma glucose levels 2 h after the ingestion of a standard 75-g glucose load, the oral glucose tolerance test (OGTT). The OGTT, however, remains inconvenient, not highly reproducible, and costly, especially for large-scale studies and population screening tests. Fasting plasma glucose (FPG) determinations are convenient, reliable, and valid measures of glucose intolerance, but the currently prescribed cut-off point of 140 mg/dl (7.8 mM) lacks sensitivity. We evaluated the reliability and validity of fasting plasma glucose (FPG) values compared with other measures of hyperglycemia for a diagnosis of diabetes in a populationbased study of carbohydrate metabolism in Wadena, Minnesota, a community of predominantly northern European ancestry. As a part of this effort, a random sample of Wadena adults, stratified by age and gender, plus all known, previously diagnosed diabetics participated in 2 days of baseline testing and were followed prospectively and retested 5 years later. Cross-sectional analyses of baseline data are presented in this article. Diabetic status was ascertained by administering a standard OGTT according to National Diabetes Data Group (NDDG) specifications. Sensitivity and specificity levels obtained when using a FPG cut-off point of 6.4 mM were 95.2% and 97.4%, respectively. In study subjects with no known diagnosis of diabetes, the FPG cut-off point of 6.4 mM performed reasonably well with a sensitivity and specificity of 67.7% and 97.4%, respectively. A receiver operating characteristic (ROC) curve analysis showed that FPG consistently performed better than glycosylated hemoglobin in distinguishing diabetic from non-diabetic subjects. FPG concentrations accurately and reliably discriminate diabetic from non-diabetic individuals in a population-based study of Caucasians of northern European ancestry.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...