Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Flow injection analysis ; Combined flow injection/HPLC ; Carbamate pesticides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An integrated flow injection (FI)/HPLC system for the total and individual determination of carbamate pesticides (propoxur, carbofuran and carbaryl) is proposed. The determination is based on the alkaline hydrolysis of the analytes and subsequent coupling with diazotized sulphanilic acid to yield the monitored dyes with or without a prior separation step by HPLC in a C18 column. The calibration curves obtained are linear in the μg/ml range and r.s.d. values are between 0.5 and 3.7% in all instances. Injection of the sample into the FI manifold allows the total pesticide content in the sample to be screened. The manifold thus acts as a post-column reactor/detector of the chromatograph for samples with high overall carbamate content, which are also injected into the HPLC instrument. The performance was checked with contaminated water samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Flow injection analysis ; Combined methods ; Transition metal ions ; Aqueous samples
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary An automatic method based on the combination of a flow injection (FI) manifold with a liquid chromatograph has been developed for the enrichment and determination of transition metal ions in water samples. Alternatively, the FI configuration can be used as a screening system for the determination of the total concentration of heavy metals. Two-parameter expressions for calibration graphs involving preconcentration time and concentration of the analytes were established for both the FIA and the integrated FIA/HPLC methods. The preconcentration time depends on the concentration level of the analytes in the samples. The method is linear in the range 2–200 ng/ml, with r.s.d. values between 1.5 and 5.0. It has been applied to the determination of copper, lead, zinc, nickel, cobalt, cadmium and manganese in synthetic water samples.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Aminopropyl-silica sorbent ; Continuous cleanup/preconcentration ; Hydroxyvitamin D3 metabolites ; Flow injection analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A new procedure for continuous cleanup and concentration of hydroxyvitamin D3 metabolites prior to their separation by HPLC and UV-detection is reported. The process is based on the use of aminopropyl-silica as solid-phase sorbent as an alternative to the use of nonpolar sorbents. The improvement thus achieved has been tested by comparing the results with those obtained using octadecyl-C18 as non-polar sorbent. The comparison has been based on the calibration graphs (linear range, detection and quantitation limits), precision and multiple standard addition method.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...