Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Fourier transform spectroscopy  (1)
  • Plug  (1)
  • 1
    ISSN: 1248-9204
    Keywords: Inguinal hernia ; Plug ; Mesh ; Groin pain
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Background The 14 day results of this study reported elsewhere demonstrated that the Perfix® plug-and-patch was as effective as the Lichtenstein patch but not as cost-effective. The present analysis looks at the results at one year to measure quality of life between the two groups. Patients and Methods 141 patients were randomly allocated in a doubleblind manner to receive either a Lichtenstein patch (patch) or a Perfix® plug- and-patch (plug-and-patch) for primary inguinal hernia. Quality of life at 6 months and one year was assessed by the short-form 36 (SF36). On a 3 point scale patients were asked at one year to rate groin, wound and testicular discomfort. Results Physical function by SF36 was similar in the 2 groups at 6 months, but at one year in the patch group (95.11 +/-20.07) was significantly better (p 〈 0.05) than physical function in the plug-and-patch group (82.5 ± 20.98). At one year the number of patients with wound discomfort limiting work or social activities was significantly greater in patients receiving the plug-and-patch (n = 12) compared with patients receiving the patch (n = 4), p 〈 0.031. At one year, 4 of 70 patients receiving the plug-and-patch had required reoperation to remove the preformed plug-and-patch device and replace it with a flat Lichtenstein patch, because of wound pain which was limiting activity. Conclusion A significant proportion of patients suffer chronic pain after placement of a Perfix® plug-and-patch for primary inguinal hernia repair. Removal of the Perfix® device is required in approximately i in 20 patients (5.6% in this series).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 273-298 
    ISSN: 1572-9559
    Keywords: Fourier transform spectroscopy ; phase correction ; interferometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract The correction of phase error in Fourier transform spectroscopy is discussed. Phase error is corrected by multiplying the inverse transform of the measured interferogram by e−iϕ(ω), where ϕ(ω) is the phase error in the spectrum. This error is determined from a low-resolution, two-sided interferogram. It is absolutely essential that the truncation-apodization function which multiplies the interferogram have an even part which is symmetric about the x=0 position. If this function is not properly located, large errors in the corrected spectrum can occur.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...