Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1572-9591
    Keywords: Cold fusion ; Pd-D2O cells ; Ti-D2 systems ; barrier penetration calculations
    Source: Springer Online Journal Archives 1860-2000
    Topics: Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract We have searched for cold fusion produced in an electrolytic cell with Pd cathode and Pt anode. The electrolyte was 0.1 molar LiOD in 99.8% D2O. A 2-mm rod of polycrystalline Pd and a 4-mm rod of single crystal Pd were used. No radiation was detected above background by a BF3 neutron and Ge γ-X detector. The D2 loading of the Pd was 0.8 D per Pd atom reaching saturation after 4 hours. We also attempted to duplicate the work of Scaramuzzi and co-workers on the Ti-D2 system. Both powder and pieces of Ti were used. The material was cycled several times between 1100 K and 77 K. No neutron, γ- or x-ray emission above background was observed. The results of a barrier penetration calculation for H-like atoms are presented. The high fusion rates reported for PdD x . are much larger than those expected from theoretical calculations on these systems.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Hoboken, NJ [u.a.] : Wiley-Blackwell
    Journal of Orthopaedic Research 1 (1983), S. 244-250 
    ISSN: 0736-0266
    Keywords: Fracture behavior ; Axial-torsional loading ; Life and Medical Sciences
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine
    Notes: This study was undertaken to determine the effect of loading rate on bone failure under singular and combined loading states. Using the entire loading range of an Instron Materials Testing Machine, 190 pairs of canine radii were tested. One bone of each pair was subjected to either torsional or a combination of axial and torsional loads, and compared with a control specimen. Compressive loads of 4.6 and 11.5 N were utilized. Torque to failure and energy data versus loading rate were plotted. As loading rate increased, the torque and energy values were found to increase, reach a peak, and then decline at higher rates. Fractures produced under the combined state of loading are representative of those clinically found in human trauma situations.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...