Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 23 (1979), S. 3147-3154 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: The transverse NMR relaxation times of hydrogen nuclei of water absorbed in white spruce sapwood [Picea glauca (Meunch) Voss] were measured for moisture contents in the range from 5 to 176%. The spin echo amplitudes resulting from the Carr-Purcell sequence decay nonexponentially suggesting the possibility of at least two different relaxation times for water in wood. A simplified structural model of the wood-water mixture is used to estimate the rates of chemical exchange at room temperature of hydrogen nuclei between various sites in the system. The high-resolution NMR line shape is discussed briefly in terms of this proposed model.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 113-114 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 115-120 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 321-326 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 164-168 
    ISSN: 0935-6304
    Keywords: Thin Layer Chromatography, HPTLC ; Fastest possible analytical mode: Anticircular separation ; First principal analytical details ; Most economical TLC/HPTLC technique, quantitative comparison with linear and circular mode ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The principal analytical details for the third of three possible modes in high performance thin-layer chromatography are given, namely the anticircular mode. Separation is achieved by allowing the mobile phase to enter the plate layer on a precise outer circle line, from where it flows towards the centre with nearly constant speed. This technique is theoretically and practically the fastest of all three possible in HPTLC. It permits maximum sample capacity with a minimum of time, layer and mobile phase consumption. It is therefore the most economical HPTLC technique.A new carrier-free mobile phase transfer principle is used. The conditions for qualitative and quantitative analysis are good: repeatability, reproducibility and accuracy of routine TLC analyses are superior to those achieved by the classical trough technique. The specially narrow spot-path in anticircular HPTLC facilitates automated quantitation. Compared with the linear and circular modes, the anticircular mode shows better separation and significantly increased sensitivity at higher Rf-values. The drawback, however, is that the separation power (expressed by the separation number) is lower compared with the other two modes.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 201-202 
    ISSN: 0935-6304
    Keywords: Gas Chromatography ; Micropacked columns ; Series-coupled ; Polarity change by temperature variation ; Temperatures independently varied in each column ; Retention index data for study of microprocessor-controlled resolution optimization ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 416-422 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; SECAT-technique=stepless fine tuning of capillary selectivity by serial column temperature optimization ; Exponential influence of temperature on selectivity over a wide range found ; SECAT-technique ready for automation of column adjustment on sample composition polarity ; Instrumental and methodological details for primitive self made solution given ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: GC, including capillary GC, is rather inflexible, if a certain column length and stationary phase has been fixed for a given analytical problem. If the sample composition changes, one often has to change the column length and/or stationary phase, at least when something like optimum analytical conditions are needed. Temperature changes (or heating rates) can change the selectivity of a given column only within very limited ranges, due to the exponential effect of temperature on retention time. By serial coupling two chemically different capillaries, each run at another temperature, even the slightest changes of these two temperature values have a dramatic effect on the selectivity of the system for polar substances. We call this technique the SECAT mode of GC. Results are reported as retention index shifts, dependent on SECAT temperature data. This technique can in future easily be automated, thus enabling the analyst, for polar sample analysis, to adjust a given chroma-tographic system to his specific sample composition without touching the instrument.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 9 (1986), S. 595-595 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Connection device ; Micro packed columns ; Macrobore capillaries ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 1 (1978), S. 9-9 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 2 (1979), S. 95-100 
    ISSN: 0935-6304
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...