  • 1
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 241-246 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Fused silica capillary columns ; Cobalt-60 gamma radiation ; Immobilized phase ; Crosslinking ; Column activity ; Temperature Stability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity.
    Zusätzliches Material: 3 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 12 (1989), S. 522-526 
    ISSN: 0935-6304
    Schlagwort(e): Gas chromatography ; Plasma emission detection ; Alternating current plasma detector ; Organolead ; Chemistry ; Analytical Chemistry and Spectroscopy
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Chemie und Pharmazie
    Notizen: The performance of the gas chromatography/alternating current plasma detector as a selective detector for organolead compounds is investigated. The helium make-up flow rate and the spatial position from which the lead emission is viewed, have an effect on the detector response. The detection limit for tetrabutyl lead was established as 130 pg/s and the lead selectivity ratio was found to exceed 13,800. Some applications of organolead determination in complex matrices were also studied in order to demonstrate the selectivity and sensitivity of the alternating current plasma detector.
    Zusätzliches Material: 6 Ill.