Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 7 (1984), S. 329-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Deactivation ; Polymethylhydrosiloxanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 10 (1987), S. 128-136 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Coating of capillaries, static and dynamic ; Rayleigh instability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The film of stationary phase on the wall of a capillary column and that of the phase solution during both static and dynamic coating is subject to Rayleigh instability, which is quite independent of so-called wettability. A theory is developed which shows that the logarithmic growth rate of Rayleigh instabilities is proportional to the surface tension and to the third power of the film thickness, and inversely to the viscosity and to the fourth power of the capillary diameter. Determination of the variation of the viscosities of stationary phase solutions with concentration in coating solvents, and the variation of the viscosities of neat stationary phases with temperature, both revealed that heating and/or diluting changed the viscosities of phases with π-electron-containing, groups much more than for polydimethylsiloxanes. Rayleigh instability is therefore more important during coating of phenyl-containing phases such as OV-17, and later during column operation. The efficiencies of capillary columns of different diameters coated with a number of phases under different conditions of temperature and coating rate, and then operated at different temperatures were in good agreement with the predictions of the theory.
    Additional Material: 8 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...