    Intensive care medicine 22 (1996), S. 199-207 
    ISSN: 1432-1238
    Schlagwort(e): Closed-loop controlled ventilation ; Human ; Initial settings ; Computer ; Mechanical ventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. Design Prospective randomized crossover study. Setting ICUs in one adult and one children's hospital in Switzerland. Patients Thirty intubated stable, critically ill patients (20 adults and 10 children). Interventions The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilator (AutoInit). Measurements and results Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V DS), expiratory time constant (RC), tidal volume (V T), total respiratory frequency (f tot), minute ventilation (MV), and maximal and mean airway pressure (P aw, max andP aw, mean) were calculated. Arterial blood gases were analyzed at the end of each period.P aw, max was significantly less with the AutoInit ventilator settings whilef tot was significantly greater (P〈0.05). The other values were not statistically significant. Conclusions The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic startup procedure for mechanical ventilation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Intensive care medicine 22 (1996), S. 199-207 
    ISSN: 1432-1238
    Schlagwort(e): Key words Closed-loop controlled ventilation ; Human ; Initial settings ; Computer ; Mechanical ventilation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Objective: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. Design: Prospective randomized crossover study. Setting: ICUs in one adult and one children’s hospital in Switzerland. Patients: Thirty intubated stable, critically ill patients (20 adults and 10 children). Interventions: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilator (AutoInit). Measurements and results: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V DS), expiratory time constant M28.6n(RC), tidal volume (V T), total respiratory frequency (f tot), minute ventilation (MV), and maximal and mean airway pressure (P aw,max and P aw,mean) were calculated. Arterial blood gases were analyzed at the end of each period. P aw,max was significantly less with the AutoInit ventilator settings while f tot was significantly greater (P〈0.05). The other values were not statistically significant. Conclusions: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...