    Medical & biological engineering & computing 21 (1983), S. 710-717 
    ISSN: 1741-0444
    Schlagwort(e): Control ; Identification ; Least squares ; Muscle relaxants ; Simulation ; State estimation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract A self-tuning algorithm is presented for the online control of muscle relaxation. Although some patient parameters were fixed at a mean value determined by offline analysis of patient data, certain parameters have been explicitly identified online. In addition the patient states are estimated and are used by a novel controller to bring an unrelaxed patient to some desired level of paralysis and maintain it. Simulations show that a twitch depression of 80% can be achieved in less than 20 min using d-tubocurarine without excessive overdosage.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Medical & biological engineering & computing 23 (1985), S. 556-564 
    ISSN: 1741-0444
    Schlagwort(e): Control ; Least squares ; Muscle relaxants ; Neuromuscular blockade ; Parameter estimation ; Simulation ; State estimation
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Biologie , Chemie und Pharmazie , Medizin
    Notizen: Abstract An existing algorithm designed to control d-tubocurarine-induced muscle relaxation in humans has been evaluated in 38 clinical trials on patients undergoing upper and lower abdominal surgery. The data captured during these trials were used to perform offline analysis of the algorithm reported on here, by which the correct functioning of the algorthm was established and its efficacy rated. It is shown that, for practical purposes, the average controller performance is close to the theoretical limit which can be achieved for this drug. The use of online parameter estimation makes precise initialisation of the controller less critical than would be the case with a fixed control low. In the trials undertaken, an average time of 12 min was needed to reach the chosen set point and excessive overshoot was avoided in every case. With a setpoint for the single twitch response of 20 per cent of the control height, the average drug consumption for the first hour of operation was 0·38 mg kg−1.