Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0878
    Keywords: Key words Neurofilament ; Basket cell ; Pinceau ; Golgi apparatus ; Calcium binding protein ; Rat
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Medicine
    Notes: Abstract NCS-1 (neuronal calcium sensor) is a recently characterized member of a highly conserved neuron-specific family of calcium-binding proteins, which also includes frequenin and recoverin. The cellular and subcellular distributions of NCS-1 in the rat nervous system were investigated using light- and electron-microscopic immunohistochemistry. NCS-1 immunoreactivity was localized to neuronal cell bodies and axons throughout the brain and spinal cord but not to glial cells. The most intense labeling was observed in myelinated axons, the axonal ramifications of the basket cell in the cerebellar cortex, and large neurons in the brainstem and pons. These same structures were also characterized by heavy labeling for neurofilament protein, as determined by double-labeling experiments. Most axon terminals were unlabeled or only lightly labeled. The most remarkable subcellular staining occurred in the perikarya where intense labeling was associated with the membranes of the trans saccules of the Golgi apparatus. The widespread distribution of NCS-1 indicates that it may be active in a variety of calcium-dependent neuronal functions, whereas the specific subcellular localization to the Golgi apparatus and neurofilament-rich structures suggests a specialized role in calcium regulated protein trafficking and cytoskeletal interactions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Journal of industrial microbiology and biotechnology 12 (1993), S. 399-402 
    ISSN: 1476-5535
    Keywords: Biological indicators ; Ethylene oxide ; Medical devices ; International standards
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: Summary Biological indicators (BIs) are used to monitor ethylene oxide (EO) gas sterilization processes for medical devices. Several European and United States BIs for EO sterilization were evaluated for resistance according to both United States Pharmacopeia (USP) XXI and United Kingdom's (UK) tests for D-values. US BIs areB. subtilis var. niger spores on paper strips or disc carriers while European BIs use aluminum strips, quartz sand, or cotton yarn. Numerous BIs per run and runs per lot, as well as 2–3 different lots of BIs from each manufacturer, were examined. Both British and US BIs met their respective label claims for rates of inactivation when tested against British and USP EO test parameters, respectively. However, Danish BIs, on cotton yarn or quartz sand, were not inactivated following USP specifications during the exposure dwell times tested (600 mg L−1 EO, 54°C, 60% RH, 0–110 min). The Danish BIs will require further testing in order for us to determine if theirB. subtilis spores are unusually resistant to EO or if the spore carrier substrates protect the spores from the sterilizing gas. In conclusion, the British and American BIs for EO sterilization are equivalent in resistance despite differences in carrier substrate, recovery conditions, calculation methods for D-values, and the labeled sterilization conditions for use.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...