Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Intensive care medicine 8 (1982), S. 93-95 
    ISSN: 1432-1238
    Keywords: Intravenous nitroglycerin ; Polyvinyl chloride tubing ; Polyethylene tubing ; Polypropylene syringe
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Two types of intravenous nitroglycerin (NTG) perfusion sets were studied using laboratory techniques. A known concentration of NTG was placed in each of these sets, and an evaluation was made as to the dose of NTG actually received by the patient after passage of the NTG solution through the sets. Set number one consisted of a glass container and polyvinyl chloride (PVC) tubing. After passage through this set, there was a rapid and significant decrease in the NTG concentration, i.e. the dose actually received by the patient is less than the dose theoretically administered. Set number two consisted of a polypropylene syringe and polyethylene tubing. After passage through this set, there was no significant change in the NTG concentration, i.e. the patient receives the full theoretical dose.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability