Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Escherichia coli  (1)
  • Intravenous therapy  (1)
  • 1
    Digitale Medien
    Digitale Medien
    Springer
    European journal of pediatrics 140 (1983), S. 118-122 
    ISSN: 1432-1076
    Schlagwort(e): Streptococci group B ; Escherichia coli ; Neonatal pneumonia ; Pulmonary disease
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Thirty-eight infants admitted to a neonatal intensive care unit because of pneumonia (14 patients) and pulmonary maladaption syndrome (PMA) (24 patients) were included in the study. Samples of potentially pathogenic, facultatively anaerobic bacteria were taken from the external ear, blood, throat, nasopharynx, umbilicus and gastric aspirates of the children, and from urethra and cervix of the mothers. Group B streptococci (GBS) and Escherichia coli were the only potentially pathogenic bacteria isolated from the infants. Out of 14 infants with pneumonia 11 (79%) harboured one of these bacteria, in contrast to 3 out of 24 (13%) with PMA (P〈0.001). GBS was found in 8/14 infants with pneumonia and in 1/24 infants with PMA (P〈0.001). The respective frequencies for Escherichia coli were 3/14 and 2/24 (not significant). The infant and/or the mother in 10/14 pneumonia cases harboured GBS, in contrast to 4/24 pairs in the PMA group (P〈0.001). The levels of antibodies against GBS in sera of mothers to infants with pneumonia did not differ from the antibody levels in control sera (parturient GBS-carriers giving birth to healthy infants). The results gave evidence for an important manifestation of neonatal GBS-infection: pneumonia without septicemia. The incidence of the disease is estimated to be 1:25 parturient GBS-carriers. Finally, maternal fever, gestational age above 42 weeks, more severe respiratory difficulties and the occurrence of severe changes in fetal heart rate during the first stage of labour were found to be typical characteristics of pneumonia, as compared to PMA.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    ISSN: 1432-1076
    Schlagwort(e): Streptococci group B ; Human gammaglobulin ; Intravenous therapy ; Neonatal septicaemia
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract A human IgG preparation was given intravenously to 36 newborn infants admitted to the neonatal intensive care unit because of suspected septicaemia. IgG was given as a single dose of 0.4 g/kg body weight. Patients serum was obtained immediately before and 30 min after terminating the infusion. Blood was also withdrawn 2 days after giving the IgG in eight of the infants. The sera were tested by radioimmunoassay for IgG antibody levels to surface antigens of group B streptococci (GBS) types Ia, Ib, II and III and to R-protein. The mean increases in anti-type Ia, Ib, II, III and R-protein antibodies 30 min after the end of infusion were 81%, 73%, 49%, 60% and 69% of the preinfusion levels, respectively. This was followed by a rapid decrease during the following 2 days to 25%–32% of the initial increases. Based on the above findings, a controlled trial of passive immunisation in the management of neonatal GBS septicaemia seems justified. The rapid decline in antibody levels would necessitate a second infusion 24 h after the initial immunoglobulin administration if the suspicion of septicaemia persists.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...