Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Engineering  (2)
  • Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm  (2)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Surgical endoscopy and other interventional techniques 10 (1996), S. 1136-1139 
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Laparoscopic surgery decreases postoperative pain and length of hospital stay. Whether laparoscopically assisted abdominal aortic aneurysm (AAA) repair can be safely and reliably performed is unknown. This prospective study was designed to establish the feasibility of laparoscopically assisted AAA repair and its effects on intraoperative and postoperative variables. Methods: With IRB approval, 10 patients with infrarenal AAA requiring a tube graft underwent laparoscopically assisted AAA repair. The procedure consisted of laparoscopic dissection of the aneurysm neck and iliac vessels. Then, through an 8–11-cm minilaparotomy, a standard endoaneurysmorrhaphy was performed. Data included laparoscopic and total operative times, blood loss, fluid requirements, duration of nasogastric suction (NGT), and lengths of intensive care unit (ICU) and postoperative hospital stays. Results: Laparoscopically assisted AAA was completed in nine of 10 patients. The first patient was converted to a standard incision because the aneurysm neck could not be adequately dissected. Laparoscopic and total operative times were 1.8 ± 0.4 and 4.5 ± 0.7 h, respectively. Mean blood loss was 1 ± 0.6 l. Intraoperative fluid requirement was 6.6 ± 1.3 l. The duration of NGT suction was 1.8 ± 1.0 days. The ICU stay was 2.1 ± 0.8 days and hospital stay was 6.7 ± 2.5 days. There were two minor complications and no deaths. Conclusions: Laparoscopically assisted AAA repair is technically feasible with acceptable blood loss, operative time, morbidity, and mortality. Potential advantages may be early removal of the NGT and shorter ICU and hospital stays. Prospective randomized trials are needed to determine if laparoscopically assisted AAA repair is advantageous.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1432-2218
    Keywords: Key words: Laparoscopy — Vascular — Abdominal aortic aneurysm
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background: Advanced laparoscopic procedures are more commonly performed in elderly patients with cardiac disease. There has been limited data on the use of pulmonary artery catheters (PAC) and transesophageal echocardiography (TEE) to monitor hemodynamic changes. Methods: We prospectively studied eight patients undergoing laparoscopic assisted abdominal aortic aneurysm repair. All patients had a PAC and all but one had an intraoperative TEE. Data included heart rate (HR), temperature (temp), pulmonary artery systolic (PAS) and diastolic (PAD) pressures, mean arterial pressure (MAP), central venous pressure (CVP), pulmonary capillary wedge pressure (PCWP), cardiac index (CI), mixed venous oxygen saturation (MVO2), and oxygen extraction ratio (O2Ex) and was obtained prior to induction, during insufflation, after desufflation, during aortic cross-clamp, and at the end of the procedure. End diastolic area (EDA), a reflection of volume status, was measured on TEE. ANOVA was used for data analysis. Results: No changes were noted in HR, temp, PAS, PCWP, CI, MVO2, and O2Ex. PAD and CVP were greater during insufflation compared with baseline and aortic cross-clamp without associated changes in EDA. MAP was higher at baseline compared with all other times during the procedure. Conclusions: Insufflation increased PAD and CVP. However, volume status as suggested by EDA and PCWP did not change. These data question the reliability of hemodynamic measurements obtained from the PAC during pneumoperitoneum and suggest that TEE may be sufficient for evaluation of volume status along with the added benefit of timely detection of ventricular wall motion abnormalities.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 39 (1996), S. 2921-2944 
    ISSN: 0029-5981
    Keywords: wavelet orthogonal bases ; wavelet-Galerkin method ; Burgers' equation ; numerical method ; approximation ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper describes exact evaluations of various finite integrals whose integrands involve products of Daubechies' compactly supported wavelets and their derivatives and/or integrals. These finite integrals play an essential role in the wavelet-Galerkin approximation of differential or integral equations on a bounded interval.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Chichester [u.a.] : Wiley-Blackwell
    International Journal for Numerical Methods in Engineering 39 (1996), S. 1199-1217 
    ISSN: 0029-5981
    Keywords: sensitivity analysis ; shape optimization ; extrusion ; drawing ; Engineering ; Engineering General
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Mathematics , Technology
    Notes: This paper develops a numerical technique for determining the shape sensitivity parameters in steady metal- forming processes such as drawing and rolling. The adjoint method is applied to the discrete non-linear system of equations in the finite element model in order to determine the discrete matrix of sensitivity parameters. In this work, two specific cases are considered. The first case involves determining the sensitivity of the process power requirement to the process geometry and the second case involves determining the sensitivity of the internal state variable distribution in the final product to the process geometry. The process geometry is assumed to be characterized by a finite number of shape parameters. The internal state variable distribution in this case represents the resistance to plastic flow and is considered to be related to the quality of the final product. Numerical examples for a simple drawing process are presented to demonstrate the efficiency of the algorithm.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...