Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1432-0428
    Keywords: Keywords Diabetic cardiovascular autonomic neuropathy ; MIBG scintigraphy ; sympathetic denervation ; autonomic function tests ; glycaemic control.
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Diabetic cardiovascular autonomic neuropathy (CAN) has been directly characterized by reduced or absent myocardial [123I]metaiodobenzylguanidine (MIBG) uptake, but there is no information available on the relationship between the myocardial adrenergic innervation defects and long-term glycaemic control. In a prospective study over a mean of 4 years we examined myocardial sympathetic innervation in 12 Type 1 (insulin-dependent) diabetic patients using MIBG scintigraphy (absolute and relative global MIBG uptake at 2 h p. i.) in conjunction with cardiovascular autonomic function tests, QTc interval, and QT dispersion. Six healthy non-diabetic subjects served as controls for the MIBG scintigraphy at baseline. HbA1c was measured twice a year. One patient, in whom MIBG accumulation was reduced maximally, died during follow up. Among the remaining patients 5 had good or borderline glycaemic control (mean HbA1c 〈 7.6 %; Group 1), whereas 6 patients were poorly controlled (mean HbA1c L 7.6 %; Group 2). Absolute global MIBG uptake increased from baseline to follow-up by 260 (−190–540) [median (range) ] cpm/g in Group 1 and decreased by −150 (−450–224) cpm/g in Group 2 (p 〈 0.05 vs Group 1). Relative global MIBG uptake decreased by −1.7 (−3.4–9.4) % in Group 1 and by −4.7 (−17.4–1.3) % in Group 2 (p 〈 0.05 vs Group 1). No differences between the groups were noted for the changes in the automatic function tests, QTc interval, and QT dispersion. In conclusion, long-term poor glycaemic control constitutes an essential determinant in the progression of left ventricular adrenergic dysinnervation which may be prevented by near-normoglycaemia. Evaluation of susceptibility to metabolic intervention may be superior when CAN is characterized directly by MIBG scintigraphy rather than by indirect autonomic function testing. [Diabetologia (1998) 41: 443–451]
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1619-7089
    Keywords: Key words: Single-photon emission tomography ; Glioma ; l-3-[123I]iodo-α-methyltyrosine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract. Single-photon emission tomography (SPET) with the amino acid analogue l-3-[123I]iodo-α-methyl tyrosine (IMT) is helpful in the diagnosis and monitoring of cerebral gliomas. Radiolabelled amino acids seem to reflect tumour infiltration more specifically than conventional methods like magnetic resonance imaging and computed tomography. Automatic tumour delineation based on maximal tumour uptake may cause an overestimation of mean tumour uptake and an underestimation of tumour extension in tumours with circumscribed peaks. The aim of this study was to develop a program for tumour delineation and calculation of mean tumour uptake which takes into account the mean background activity and is thus optimised to the problem of tumour definition in IMT SPET. Using the frequency distribution of pixel intensities of the tomograms a program was developed which automatically detects a reference brain region and draws an isocontour region around the tumour taking into account mean brain radioactivity. Tumour area and tumour/brain ratios were calculated. A three-compartment phantom was simulated to test the program. The program was applied to IMT SPET studies of 20 patients with cerebral gliomas and was compared to the results of manual analysis by three different investigators. Activity ratios and chamber extension of the phantom were correctly calculated by the automatic analysis. A method based on image maxima alone failed to determine chamber extension correctly. Manual region of interest analysis in patient studies resulted in a mean inter-observer standard deviation of 8.7%±6.1% (range 2.7%–25.0%). The mean value of the results of the manual analysis showed a significant correlation to the results of the automatic analysis (r = 0.91, P〈0.0001 for the uptake ratio; r = 0.87, P〈0.0001 for the tumour area). We conclude that the algorithm proposed simplifies the calculation of uptake ratios and may be used for observer-independent evaluation of IMT SPET studies. Three-dimensional tumour recognition and transfer to co-registered morphological images based on this program may be useful for the planning of surgical and radiation treatment.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...