Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Key words: Magnetic resonance (MR), comparative studies—Uterine neoplasms, diagnosis—Uterine neoplasms, MR—Uterine neoplasms, staging—Uterus, radiography.  (1)
  • Key words Cationic surfactant mixture  (1)
  • 1
    ISSN: 1432-0509
    Schlagwort(e): Key words: Magnetic resonance (MR), comparative studies—Uterine neoplasms, diagnosis—Uterine neoplasms, MR—Uterine neoplasms, staging—Uterus, radiography.
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract Background: To investigate the efficacy of thin-section oblique axial T2-weighted images in the assessment of parametrial invasion by cervical carcinoma. Methods: One hundred parametria of 50 patients with cervical carcinoma were evaluated with pathologic correlation. We compared the sensitivity, specificity, and diagnostic accuracy in the assessment of parametrial invasion by cervical carcinoma between axial T2-weighted images and thin-section oblique axial T2-weighted images. Results: Thin-section oblique axial T2-weighted images provided accurate cross sections of the cervix with excellent detail and detected parametrial invasion more accurately than did axial T2-weighted images showing cross sections of the trunk. Although the sensitivity, specificity, and accuracy for parametrial invasion were 46.4%, 91.7%, and 79.0%, respectively, on axial T2-weighted images, the corresponding values were 67.9%, 97.2%, and 89.0%, respectively, on thin-section oblique axial T2-weighted images. There were statistically significant differences in the sensitivity (p = 0.014), specificity (p = 0.046), and accuracy (p = 0.002) in detecting parametrial invasion between these two types of images. Conclusions: Thin-section oblique axial T2-weighted images are useful for the assessment of parametrial invasion by cervical carcinoma.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Springer
    Colloid & polymer science 275 (1997), S. 958-963 
    ISSN: 1435-1536
    Schlagwort(e): Key words Cationic surfactant mixture ; fluorocarbon quencher ; micropolarity ; micellar immiscibility ; pyrene fluorescence quenching
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Chemie und Pharmazie , Maschinenbau
    Notizen: Abstract  Fluorescence-quenching of pyrene in micellar system has been investigated using 1,1,2,2-tetrahydroheptadecafluorodecylpyridinium chloride (HFDePC). The new fluorocarbon quencher has a similar quenching ability as hexadecyl-pyridinium chloride (CPC) towards pyrene in hydrocarbon micelles if only a quencher molecule is solubilized in a micelle. The fluorocarbon quencher randomly distributed among micelles if the average occupancy number of probes per a micelle was small enough. The fluorescence behavior of pyrene was examined for hexadecyl-trimethylammonium chloride (CTAC) and HFDePC mixtures. The variation of fluorescence intensity gave second cmc, reflecting the micellar immiscibility of fluorocarbon and hydrocarbon surfactants. The second cmc can be simulated by material balances of both surfactants supposing the coexistence of two kinds of mixed micelles. The fluorescence-quenching behavior suggested the enhanced micellar immiscibility probably due to nonrandom distribution of fluorocarbon quenchers among micelles.