Bibliothek

feed icon rss

Ihre E-Mail wurde erfolgreich gesendet. Bitte prüfen Sie Ihren Maileingang.

Leider ist ein Fehler beim E-Mail-Versand aufgetreten. Bitte versuchen Sie es erneut.

Vorgang fortführen?

Exportieren
Filter
  • Finite Volume  (1)
  • Key words Isolated murine heart  (1)
  • 1
    ISSN: 1432-2013
    Schlagwort(e): Key words Isolated murine heart ; Antegrade perfusion ; Functional stability ; High-energy phosphates
    Quelle: Springer Online Journal Archives 1860-2000
    Thema: Medizin
    Notizen: Abstract  An improved, isolated, left ventricular-ejecting, murine heart model is described and evaluated. Special attention was paid to the design and impedance characteristics of the artificial aortic outflow tract and perfusate composition, which contained glucose (10 mM plus insulin) and pyruvate (1.5 mM) as substrates. Temperature of the isolated perfused hearts was maintained at 38.5 °C. During antegrade perfusion (preload 10 mm Hg, afterload 50 mm Hg, 2.5 mM Ca2+) proper design of the aortic outflow tract provided baseline values for cardiac output (CO), left ventricular developed pressure (LVDP) and the maximum first derivative of left ventricular pressure (LV dP/dt max) of 11.1±1.7 ml min–1, 83±5 mm Hg and 6283±552 mm Hg s–1, respectively, resembling findings in the intact mouse. During 100 min normoxic antegrade perfusion CO declined non-significantly by less than 10%. Varying pre- and afterloads resulted in typical Frank-Starling relationships with maximal CO values of 18.6±1.8 ml min–1 at pre- and afterload pressures of 25 and 50 mm Hg, respectively. Left ventricular function curves were constructed at free [Ca2+] of 1.5 and 2.5 mM in the perfusion medium. Significantly higher values for CO, LVDP and LV dP/dt max and LV dP/dt min were obtained at 2.5 mM Ca2+ at all loading conditions investigated. Phosphocreatine and creatine levels remained stable throughout the perfusion period. Despite a small but significant decline in tissue ATP content, the sum of adenine nucleotides did not change during the normoxic perfusion period. The tissue content of glycogen increased significantly.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
  • 2
    Digitale Medien
    Digitale Medien
    Chichester : Wiley-Blackwell
    International Journal for Numerical Methods in Fluids 4 (1984), S. 1083-1095 
    ISSN: 0271-2091
    Schlagwort(e): Turbomachines ; Finite Volume ; Consistency ; Engineering ; Engineering General
    Quelle: Wiley InterScience Backfile Collection 1832-2000
    Thema: Maschinenbau
    Notizen: The aim of this contribution is to investigate the consistency and order of accuracy of different control surfaces used for finite area blade-to-blade flow calculations. The following cases will be treated: a hexagonal element, a trapezoidal element, a bitrapezoidal element and a quadrilateral element. Finally, the consistency conditions will be discussed and compared with respect to a cascade flow application.
    Zusätzliches Material: 6 Ill.
    Materialart: Digitale Medien
    Bibliothek Standort Signatur Band/Heft/Jahr Verfügbarkeit
    BibTip Andere fanden auch interessant ...
Schließen ⊗
Diese Webseite nutzt Cookies und das Analyse-Tool Matomo. Weitere Informationen finden Sie hier...