Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Analytical Chemistry and Spectroscopy  (2)
  • Key words Behavioral sensitization  (1)
Material
Years
Keywords
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Psychopharmacology 134 (1997), S. 221-229 
    ISSN: 1432-2072
    Keywords: Key words Behavioral sensitization ; Dopamine ; Amphetamine ; Rat ; Microdialysis ; Caudate putamen ; Nucleus accumbens
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract The repeated administration of amphetamine (AMPH) results in a pattern of behavioral changes which includes an augmentation of some behaviors, generally referred to as behavioral sensitization. Some investigators have suggested that an increased dopamine (DA) response to AMPH challenge may underlie behavioral sensitization, while others have reported behavioral sensitization in the absence of an enhanced DA response. Because temporal and dosage parameters of the AMPH pretreatment regimen have been suggested to play a role in the appearance of an enhanced DA response, we utilized a variety of AMPH pretreatment regimens to assess the relationship between pretreatment dose of AMPH, duration of withdrawal and the DA response in caudate-putamen and nucleus accumbens to a subsequent AMPH challenge. Under our experimental conditions, behavioral sensitization was observed after each of these treatments in the absence of an enhanced DA response in either brain region.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 8 (1994), S. 996-1000 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: Massive-cluster impact (MCI) ionization was found to be capable of producing high secondary-ion yields from biological samples without the use of a liquid matrix. Dry samples of molecules as large as cytochrome c were observed to be efficiently desorbed without significant fragmentation by the MCI beam of glycerol clusters. In addition, signals from protonated molecules retained a significant proportion of their initial intensity even after several minutes exposure to the primary beam. It was determined that these remarkable phenomena are not the result of the build-up of a layer of glycerol caused by the cluster bombardment.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY : Wiley-Blackwell
    Rapid Communications in Mass Spectrometry 9 (1995), S. 1321-1324 
    ISSN: 0951-4198
    Keywords: Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Physics
    Notes: A focused Cs+ beam was used to obtain secondary ion mass spectra and images from samples of stearic acid on gold before and after ablation by a beam of masive cluster ions. Ablation appears to have two effects on secondary ion emission. First, the number and intensity of peaks reflecting contamination are substantially reduced. Secondly, the absolute intensity of secondary ion current characteristic of the analyte increases. These features simplify mass spectra and improve contrast in the images obtained.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...