Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    ISSN: 1435-1285
    Keywords: Key words Intravascular ultrasound – coronary artery disease – plaque tissue characterization
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary Previous studies correlating histomorphology with 20–30 MHz-derived intravascular ultrasound (IVUS) images showed that IVUS provides to some extent qualitative information on plaque composition. IVUS imaging proved to define calcifications with high sensitivity and specificity but was found to be less accurate in the assessment of soft components. Nevertheless previous studies on atherosclerotic plaque characterization were limited by use of low-frequency transducers that did not define accurately soft components. Our goal was to test the effectiveness of high frequency IVUS transducers in the identification of lipid/necrotic pools in atherosclerotic plaques. Methods: Forty MHz transducers were used for in vitro IVUS assessment of 12 arterial segments (10 coronary arteries and 2 carotid arteries dissected from 5 different autopsy cases). IVUS acquisition was performed at a 0.5 mm/s speed after ligature of the branching points to generate a closed system. Lipid necrotic areas were defined by IVUS as large echolucent intraplaque areas surrounded by tissue with higher echodensity. To obtain histopathologic sections corresponding to IVUS cross sections, vessels were divided into consecutive 3 mm-long segments using the most distal recorded IVUS image as the starting reference. Then, samples were fixed with 10% buffered formalin, processed for histopathologic study, serially cut, and stained with the Movat penthacrome method. Results: One hundred twenty-two sections were analyzed. Lipid pools were observed by histology in 30 cross sections (25%). IVUS revealed the presence of lipid pools in 19 of 122 cross sections with a sensitivity and specificity of 67% and 94%, respectively. Conclusions: High frequency transducers accurately identify lipid/necrotic pools and open new perspectives on future IVUS characterization of atherosclerotic plaques.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...