Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    International journal of clinical oncology 5 (2000), S. 334-336 
    ISSN: 1437-7772
    Keywords: Key words Prostate cancer ; IgE myeloma ; Asymptomatic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract An unusual case of the simultaneous occurrence of prostate cancer and IgE myeloma is reported. A 74-year-old man with urinary disturbance and elevated serum prostate-specific antigen level, of 7.4 ng/ml, showed Bence-Jones protein in the urine. Immunoelectrophoresis of the serum showed elevation of IgE kappa monoclonal protein. Radical prostatectomy was performed as a curative therapy for T1c, Gleason 3-2 prostate cancer. The patient has remained free of progression of both the myeloma and the prostate cancer for 26 months after the initial diagnosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1437-7772
    Keywords: Key words Prostate cancer ; Systematic biopsy ; Transrectal ultrasonography ; Prostate-specific antigen ; T1c cancer
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Background. Random systematic biopsy is widely utilized for the diagnosis of prostate cancer. The standard method seems to be transrectal ultrasonography (TRUS)-guided sextant transrectal biopsy. In this study, the results of a TRUS-guided transperineal technique were evaluated. Methods. Between 1993 and 1996, 102 patients were diagnosed with prostate cancer by random systematic transperineal biopsy. Eight cores (four from the ventral side and four from the rectal side) were taken from each patient while the longitudinal section was monitored by TRUS. The lengths of the whole core and the cancerous lesion were measured in each biopsy specimen. The results of systematic biopsy were examined in relation to the findings of digital rectal examination (T category), histological grade, clinical stage, and serum level of prostate-specific antigen (PSA). Results. The number of positive cores increased with the T category. The percentage of cancers in the biopsy specimens also increased according to T category. In patients without metastasis, there was a weak correlation between the level of serum PSA and the cube of the total lengths of cancerous lesions in the biopsy specimens. Nonpalpable T1 cancers had more positive cores and a greater percentage of cancer on the ventral side, while in palpable cancers, cancerous tissues were found more often and at a greater incidence on the rectal side. Conclusion. There was a correlation between the clinical stage of prostate cancer and the pathological findings of random systematic transperineal biopsy under TRUS guidance.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    International journal of clinical oncology 5 (2000), S. 345-354 
    ISSN: 1437-7772
    Keywords: Key words Prostate cancer ; Chromosome ; Loss of heterozygosity ; Tumor suppressor gene ; Metastasis suppressor gene
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Cytogenetic, molecular cytogenetic, and molecular studies of prostate cancer have produced a large volume of data about chromosomal loci that are aberrant in prostate cancer. The cumulative data on prostate cancer reveal allelic losses on chromosome arms 2q, 3p, 5q, 6q, 7q, 8p, 9p, 10p, 10q, 11p, 11q, 12p, 13q, 16q, 17p, 17q, 18q, and 21q, but there is a great deal of variability between studies. In most cases, the frequency of allelic loss is higher in metastatic tissues or hormone-refractory tumors than in primary tumors. There also seem to be discrepancies in the genetic findings depending on methods employed. Molecular genetic studies, using polymerase chain reaction (PCR) analysis of microsatellite markers, demonstrated allelic loss at 7q31.1, whereas fluorescence in situ hybridization analysis showed a gain at the same region. Com-mon sites of allelic loss that are consistently observed by various methods seem to exist on chromosome arms 8p, 10q, 13q, and 16q. PTEN/MMAC1 has been identified on 10q23.3 and was found to be frequently mutated in advanced prostate cancer. Other regions are also considered to harbor genes associated with the development and progression of prostate cancer, and these could be included in the diagnostic methods for the substaging of prostate cancer.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 5 (1984), S. 1039-1052 
    ISSN: 1572-9559
    Keywords: H2O laser ; Faraday rotation ; polarimetry ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A fast response frequency-modulated interferometric polarimeter was designed and constructed with a single 28 μm H2O laser for high density plasma diagnostics. This newly developed modulation system employs an electro-magnetically driven movable mirror to achieve the modulation frequency beyound 1 MHz for about 100 μs duration. The movable mirror performance is studied experimentally in detail. The determination of the Faraday rotation angle is based on the zero-crossing method for the observed beat signals produced by two kinds of rotating plane-polarized waves. The feasibility of the polarimeter constructed was verified in experiments of a field-reversed thetapinch plasma.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 2 (1981), S. 1199-1208 
    ISSN: 1572-9559
    Keywords: water vapor laser ; plasma diagnostics ; interferometer ; waveguide laser ; far-infrared
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water vapor laser has been constructed in order to use as a light source of an interferometer for plasma diagnostics. The laser consists of 220 cm length and 2.0 cm small bore Pyrex glass discharge tube, semi-confocal resonator and Michelson coupler. From the measurement of cavity detuning curves, it is found that two waveguide modes, EH11 and EH21 oscillate. The increase of the output power is found to become more than seven times larger by adding He(50%)−H2(50%) mixed gas. Under the optimum condition, the maximum output power of 65 mW or the output power per unit cavity volume of 83 μW/cm3 is obtained.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    Electronic Resource
    Electronic Resource
    Springer
    International journal of infrared and millimeter waves 4 (1983), S. 549-559 
    ISSN: 1572-9559
    Keywords: interferometer ; polarimeter ; water-vapor laser ; far-infrared ; plasma diagnostics ; compact toroid
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract A high-power CW 27.972 μm water-vapor laser has been developed for interferometric and polarimetric measurements of plasmas. The maximum output power and the power density in the cavity of the laser with 2.0 cm bore and 220 cm length reach 85 mW and 109 μW/cm3, respectively. An interferometer using this laser is constructed and its performance is examined as a study on polarimetric method of magnetic field measurement. Preliminary interferometric experiments are also carried out on a compact toroidal plasma with field-reversal configuration.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...